Send Message
Good price  online

products details

Home > Products >
Cooling Towers
>
60 Ton Cooling Towers 380V 3 Phase 50Hz Chiller Tower

60 Ton Cooling Towers 380V 3 Phase 50Hz Chiller Tower

Brand Name: ANGES
Model Number: 60ton
MOQ: 1
Packaging Details: Plywood case
Payment Terms: T/T
Detail Information
Place of Origin:
China
Cooling Capacity:
234000kcal/h
Nominal Flow:
46.8m3/h
Power:
380V/3P/50Hz
Height × Diameter(H×φ):
2700×1980mm
Inlet Pipe Caliber:
100mm
Outlet Pipe Caliber:
100mm
Brand:
Anges
High Light:

60 Ton Cooling Towers

,

Cooling Towers 380V

,

50Hz chiller tower

Product Description

60tons cooling  tower technical parameters

Model STG-60

Basic parameter

Type Counter current circular cooling tower
  Nominal flow 46.8m3/h
  Inlet/outlet temperature 37℃/32℃
  Dry-bulb temperature 31.5℃
  Wet-bulb temperature 27℃
  Cooling capacity 234000kcal/h
  Noise (dB(A)) 61dB(A)
  Power 380V/3P/50Hz
  Water quality PH=6 to 8
  N.W/G.W 240kg/1250kg
Fan Fan type Axial Flow
  Cooling air flow(m3/h) 28080m3/h
  Rotation speed(r/min) 710r/min
  Diameter 930 mm
  Quantity 4 pieces/set
  Electronic box Water proof type
  Power 1.1kw
  Start-up mode Direct start

 

Size

Height × diameter(H×φ) 2700×1980mm
  Inlet pipe caliber 100mm
  Outlet pipe caliber 100mm
  Full outlet/drain off pipe caliber 25mm/25mm
  water supply pipe caliber 20mm
Material Sprinkler P.V.C-U
  Casing Fiberglass
  Water basin  
  Fan A.B.S.
  Electronic box Water proof type
  In -fill P.V.C.
  Shelf Hot-dip galvanized steel
 

WORKING PRINCIPLE

  1. A cooling tower is designed to remove heat from a building or facility by spraying water down through the tower to exchange heat into the inside of the building. Air comes in from the sides of the tower and passes through the falling water.

  2. A cooling tower is a device that rejects waste heat to the atmosphere through the cooling of a coolant stream, usually a water stream to a lower temperature.

  3. Cooling towers may either use the evaporation of water to remove process heat and cool the working fluid to near the wet-bulb air temperature or, in the case of dry cooling towers, rely solely on air to cool the working fluid to near the dry-bulb air temperature using radiators.

  • Advantages

  1. Tower body temperature weight: reduce the design requirements for the foundation and installation costs.

  2. The cooling water volume of the tower can be adjusted: for a given type of cold water tower, with working water pressure change (that is, flow change) in and out of the water temperature difference is generally unchanged, so you can increase the water supply pressure method to improve the cooling water volume of the tower (within the scope of the spray device), but also can change the nozzle aperture method to adjust the tower water volume and temperature drop.

  3. No plugging, no maintenance, stable and reliable operation. A series of phenomena that affect the performance of the tower and process system equipment such as the plugging of the packing column due to the impurities in the circulating water, the aging of the packing, the deformation, the brittle-cracking, the plugging and flushing of the sprinkler head, the plugging of the packing brittle-chip in the pipeline, the pump and the heat exchanger are completely eliminated. It completely eliminates the trouble of frequent cleaning, replacement of filler and spray nozzle

  • Main Features

  1. Small floating water rate: the spray device is evenly distributed in the tower, and the outlet area is about twice as large as that of the traditional power tower, so the wind speed is small. At the same time, the top of the tower is installed with excellent performance of the water collection device, which minimizes the amount of floating water, and eliminates a lot of water refill.

  2. ​ Good cooling effect: the hot water in the tower exchanges heat with the incoming air under the condition of mist. Due to the small wind resistance in the tower and the reasonable design of air duct and wind blade, the ratio of air to water is improved.

  3. Common applications include cooling the circulating water used in oil refineries, petrochemical and other chemical plants, thermal power stations, nuclear power stations and HVAC systems for cooling buildings. The classification is based on the type of air induction into the tower: the main types of cooling towers are natural draft and induced draft cooling towers.

Products Details

Home > Products >
Cooling Towers
>
60 Ton Cooling Towers 380V 3 Phase 50Hz Chiller Tower

60 Ton Cooling Towers 380V 3 Phase 50Hz Chiller Tower

Brand Name: ANGES
Model Number: 60ton
MOQ: 1
Packaging Details: Plywood case
Payment Terms: T/T
Detail Information
Place of Origin:
China
Brand Name:
ANGES
Model Number:
60ton
Cooling Capacity:
234000kcal/h
Nominal Flow:
46.8m3/h
Power:
380V/3P/50Hz
Height × Diameter(H×φ):
2700×1980mm
Inlet Pipe Caliber:
100mm
Outlet Pipe Caliber:
100mm
Brand:
Anges
Minimum Order Quantity:
1
Packaging Details:
Plywood case
Delivery Time:
15 days
Payment Terms:
T/T
High Light:

60 Ton Cooling Towers

,

Cooling Towers 380V

,

50Hz chiller tower

Product Description

60tons cooling  tower technical parameters

Model STG-60

Basic parameter

Type Counter current circular cooling tower
  Nominal flow 46.8m3/h
  Inlet/outlet temperature 37℃/32℃
  Dry-bulb temperature 31.5℃
  Wet-bulb temperature 27℃
  Cooling capacity 234000kcal/h
  Noise (dB(A)) 61dB(A)
  Power 380V/3P/50Hz
  Water quality PH=6 to 8
  N.W/G.W 240kg/1250kg
Fan Fan type Axial Flow
  Cooling air flow(m3/h) 28080m3/h
  Rotation speed(r/min) 710r/min
  Diameter 930 mm
  Quantity 4 pieces/set
  Electronic box Water proof type
  Power 1.1kw
  Start-up mode Direct start

 

Size

Height × diameter(H×φ) 2700×1980mm
  Inlet pipe caliber 100mm
  Outlet pipe caliber 100mm
  Full outlet/drain off pipe caliber 25mm/25mm
  water supply pipe caliber 20mm
Material Sprinkler P.V.C-U
  Casing Fiberglass
  Water basin  
  Fan A.B.S.
  Electronic box Water proof type
  In -fill P.V.C.
  Shelf Hot-dip galvanized steel
 

WORKING PRINCIPLE

  1. A cooling tower is designed to remove heat from a building or facility by spraying water down through the tower to exchange heat into the inside of the building. Air comes in from the sides of the tower and passes through the falling water.

  2. A cooling tower is a device that rejects waste heat to the atmosphere through the cooling of a coolant stream, usually a water stream to a lower temperature.

  3. Cooling towers may either use the evaporation of water to remove process heat and cool the working fluid to near the wet-bulb air temperature or, in the case of dry cooling towers, rely solely on air to cool the working fluid to near the dry-bulb air temperature using radiators.

  • Advantages

  1. Tower body temperature weight: reduce the design requirements for the foundation and installation costs.

  2. The cooling water volume of the tower can be adjusted: for a given type of cold water tower, with working water pressure change (that is, flow change) in and out of the water temperature difference is generally unchanged, so you can increase the water supply pressure method to improve the cooling water volume of the tower (within the scope of the spray device), but also can change the nozzle aperture method to adjust the tower water volume and temperature drop.

  3. No plugging, no maintenance, stable and reliable operation. A series of phenomena that affect the performance of the tower and process system equipment such as the plugging of the packing column due to the impurities in the circulating water, the aging of the packing, the deformation, the brittle-cracking, the plugging and flushing of the sprinkler head, the plugging of the packing brittle-chip in the pipeline, the pump and the heat exchanger are completely eliminated. It completely eliminates the trouble of frequent cleaning, replacement of filler and spray nozzle

  • Main Features

  1. Small floating water rate: the spray device is evenly distributed in the tower, and the outlet area is about twice as large as that of the traditional power tower, so the wind speed is small. At the same time, the top of the tower is installed with excellent performance of the water collection device, which minimizes the amount of floating water, and eliminates a lot of water refill.

  2. ​ Good cooling effect: the hot water in the tower exchanges heat with the incoming air under the condition of mist. Due to the small wind resistance in the tower and the reasonable design of air duct and wind blade, the ratio of air to water is improved.

  3. Common applications include cooling the circulating water used in oil refineries, petrochemical and other chemical plants, thermal power stations, nuclear power stations and HVAC systems for cooling buildings. The classification is based on the type of air induction into the tower: the main types of cooling towers are natural draft and induced draft cooling towers.