Send Message
Good price  online

products details

Home > Products >
Cooling Towers
>
40 Ton Hvac Free Cooling Towers And Chillers 380V

40 Ton Hvac Free Cooling Towers And Chillers 380V

Brand Name: ANGES
Model Number: 40ton
MOQ: 1
Packaging Details: Plywood case
Payment Terms: T/T
Detail Information
Place of Origin:
China
Cooling Capacity:
156050kcal/h
Nominal Flow:
31.21m3/h
Power:
380V/3P/50Hz
Height × Diameter(H×φ):
2500×1600mm
Inlet Pipe Caliber:
80mm
Outlet Pipe Caliber:
80mm
Brand:
Anges
High Light:

40 ton cooling towers and chillers

,

hvac cooling towers and chillers

,

40 ton chiller cooling tower

Product Description

40tons cooling  tower technical parameters
 

ModelSTG-40

 

 

 

 

 

Basic parameter

TypeCounter current circular cooling tower
Nominal flow31.21m3/h
Inlet/outlet temperature37℃/32℃
Dry-bulb temperature31.5℃
Wet-bulb temperature27℃
Cooling capacity156050kcal/h
Noise (dB(A))60dB(A)
Power380V/3P/50Hz
Water qualityPH=6 to 8
N.W/G.W130kg/550kg
FanFan typeAxial Flow
Cooling air flow(m3/h)18726m3/h
Rotation speed(r/min)710r/min
Diameter770 mm
Quantity4 pieces/set
Electronic boxWater proof type
Power1.5kw
Start-up modeDirect start

 

Size

Height × diameter(H×φ)2500×1600mm
Inlet pipe caliber80mm
Outlet pipe caliber80mm
Full outlet/drain off pipe caliber25mm/25mm
water supply pipe caliber15mm
MaterialSprinklerP.V.C-U
CasingFiberglass
Water basin
FanPolyamide
Electronic boxWater proof type
In -fillP.V.C.
ShelfHot-dip galvanized steel

 

 

WORKING PRINCIPLE

 

  Cooling tower is a heat removal device that cools water vapor into cooler water, discharging waste heat from a system to the atmosphere.
  Cooling tower is a specialized heat exchanger in which air and water are brought into direct contact with each other in order to reduce the water’s temperature. As this occurs, a small volume of water is evaporated, reducing the temperature of the water being circulated through the tower.

 

MAIN FEATURE

1. Air conditioning equipment and industrial processes can generate heat in the form of tons of hot water that needs to be cooled down. That’s where an industrial cooling tower comes in. Overheated water flows through the cooling tower where it’s recirculated and exposed to cool, dry air.

2. Heat leaves the recirculating cooling tower water through evaporation. The colder water then reenters the air conditioning equipment or process to cool that equipment down, and the cooling cycle repeats over and over again.

3. When the warm condenser goes into the cooling tower, the water is passed through some nozzles which spray the water into small droplets across the fill, which increases the surface area of water and allows for better heat loss thru greater evaporation.

4. The purpose of the fan on top of the water cooling tower is to bring in air from the bottom of the tower and move it up and out in the opposite direction of the warm condenser water at the top of the unit. The air will carry the heat through evaporating water from the cooling tower into the atmosphere.

 

Products Details

Home > Products >
Cooling Towers
>
40 Ton Hvac Free Cooling Towers And Chillers 380V

40 Ton Hvac Free Cooling Towers And Chillers 380V

Brand Name: ANGES
Model Number: 40ton
MOQ: 1
Packaging Details: Plywood case
Payment Terms: T/T
Detail Information
Place of Origin:
China
Brand Name:
ANGES
Model Number:
40ton
Cooling Capacity:
156050kcal/h
Nominal Flow:
31.21m3/h
Power:
380V/3P/50Hz
Height × Diameter(H×φ):
2500×1600mm
Inlet Pipe Caliber:
80mm
Outlet Pipe Caliber:
80mm
Brand:
Anges
Minimum Order Quantity:
1
Packaging Details:
Plywood case
Delivery Time:
15 days
Payment Terms:
T/T
High Light:

40 ton cooling towers and chillers

,

hvac cooling towers and chillers

,

40 ton chiller cooling tower

Product Description

40tons cooling  tower technical parameters
 

ModelSTG-40

 

 

 

 

 

Basic parameter

TypeCounter current circular cooling tower
Nominal flow31.21m3/h
Inlet/outlet temperature37℃/32℃
Dry-bulb temperature31.5℃
Wet-bulb temperature27℃
Cooling capacity156050kcal/h
Noise (dB(A))60dB(A)
Power380V/3P/50Hz
Water qualityPH=6 to 8
N.W/G.W130kg/550kg
FanFan typeAxial Flow
Cooling air flow(m3/h)18726m3/h
Rotation speed(r/min)710r/min
Diameter770 mm
Quantity4 pieces/set
Electronic boxWater proof type
Power1.5kw
Start-up modeDirect start

 

Size

Height × diameter(H×φ)2500×1600mm
Inlet pipe caliber80mm
Outlet pipe caliber80mm
Full outlet/drain off pipe caliber25mm/25mm
water supply pipe caliber15mm
MaterialSprinklerP.V.C-U
CasingFiberglass
Water basin
FanPolyamide
Electronic boxWater proof type
In -fillP.V.C.
ShelfHot-dip galvanized steel

 

 

WORKING PRINCIPLE

 

  Cooling tower is a heat removal device that cools water vapor into cooler water, discharging waste heat from a system to the atmosphere.
  Cooling tower is a specialized heat exchanger in which air and water are brought into direct contact with each other in order to reduce the water’s temperature. As this occurs, a small volume of water is evaporated, reducing the temperature of the water being circulated through the tower.

 

MAIN FEATURE

1. Air conditioning equipment and industrial processes can generate heat in the form of tons of hot water that needs to be cooled down. That’s where an industrial cooling tower comes in. Overheated water flows through the cooling tower where it’s recirculated and exposed to cool, dry air.

2. Heat leaves the recirculating cooling tower water through evaporation. The colder water then reenters the air conditioning equipment or process to cool that equipment down, and the cooling cycle repeats over and over again.

3. When the warm condenser goes into the cooling tower, the water is passed through some nozzles which spray the water into small droplets across the fill, which increases the surface area of water and allows for better heat loss thru greater evaporation.

4. The purpose of the fan on top of the water cooling tower is to bring in air from the bottom of the tower and move it up and out in the opposite direction of the warm condenser water at the top of the unit. The air will carry the heat through evaporating water from the cooling tower into the atmosphere.