Brand Name: | ANGES |
Model Number: | Inverter Chiller |
MOQ: | 1 |
VFD Chiller Inverter Chiller Variable Speed Chiller 12ton Portable Water Cooled Chiller Recirculating Chiller
About the inverter chiller
Water chiller with non-inverter type compressor remains constant water temperature by adjusting the compressor's ON and OFF, which consumes more energy.
In inverter type water chiller,water temperature is adjusted by changing compressor motor speed instead of ON and OFF.
With Variable Frequency Drive (VFD) technology, water chillers are able to match the varying load requirements from production process to control running speed, regardless of requirement.
Specification
Item |
AWV-12 | |
Nominal cooling capacity | Low frequency kcal/h | 8835 |
High frequency kcal/h | 31806 | |
Low frequency kw | 10.27 | |
High frequency kw | 36.98 | |
Input power | Low frequency kw | 3.59 |
High frequency kw | 9.02 | |
Power | Variable frequency power supply | |
Refrigerant | Type | R410a |
Type of control | Electronic expansion valve | |
Compressor | Type | Hermetic motor driven compressor |
Low frequency power( kw) | 2.09 | |
High frequency power (kw) | 7.52 | |
Condenser | Type | Shell and tube |
Cooling water flow (m3/h) | 7.7 | |
Inlet and outlet pipe caliber(inch) | 2 | |
Evaporator | Type | Water tank with coil |
Chilled water flow (m3/h) | 6.4 | |
T | Tank volume(L) | 180 |
Inlet and outlet pipe caliber(inch) | 2 | |
Pump | Power (kw) | 1.5 |
Lift(m) | 20 | |
Safety protection | compressor over temperature, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing | |
Dimension | mm | 1320*710*1320 |
Weight | kg | 500 |
Features and benefits of VFD water chiller
Chiller service
Brand Name: | ANGES |
Model Number: | Inverter Chiller |
MOQ: | 1 |
VFD Chiller Inverter Chiller Variable Speed Chiller 12ton Portable Water Cooled Chiller Recirculating Chiller
About the inverter chiller
Water chiller with non-inverter type compressor remains constant water temperature by adjusting the compressor's ON and OFF, which consumes more energy.
In inverter type water chiller,water temperature is adjusted by changing compressor motor speed instead of ON and OFF.
With Variable Frequency Drive (VFD) technology, water chillers are able to match the varying load requirements from production process to control running speed, regardless of requirement.
Specification
Item |
AWV-12 | |
Nominal cooling capacity | Low frequency kcal/h | 8835 |
High frequency kcal/h | 31806 | |
Low frequency kw | 10.27 | |
High frequency kw | 36.98 | |
Input power | Low frequency kw | 3.59 |
High frequency kw | 9.02 | |
Power | Variable frequency power supply | |
Refrigerant | Type | R410a |
Type of control | Electronic expansion valve | |
Compressor | Type | Hermetic motor driven compressor |
Low frequency power( kw) | 2.09 | |
High frequency power (kw) | 7.52 | |
Condenser | Type | Shell and tube |
Cooling water flow (m3/h) | 7.7 | |
Inlet and outlet pipe caliber(inch) | 2 | |
Evaporator | Type | Water tank with coil |
Chilled water flow (m3/h) | 6.4 | |
T | Tank volume(L) | 180 |
Inlet and outlet pipe caliber(inch) | 2 | |
Pump | Power (kw) | 1.5 |
Lift(m) | 20 | |
Safety protection | compressor over temperature, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing | |
Dimension | mm | 1320*710*1320 |
Weight | kg | 500 |
Features and benefits of VFD water chiller
Chiller service