logo
Home > products > Industrial Water Chiller >
3HP Air Cooled Scroll Chiller Industrial Process Air Chillers For Printing And BOPP Film Lamination Line

3HP Air Cooled Scroll Chiller Industrial Process Air Chillers For Printing And BOPP Film Lamination Line

3HP Air Cooled Scroll Chiller

Air Cooled Scroll Chiller For Printing

Industrial Process Air Chillers

Place of Origin:

China

Brand Name:

ANGES

Model Number:

3hp

Contact Us
Request A Quote
Product Details
Cooling Capacity:
8.5 Kw
Water Tank Capacity:
20L
Voltage:
3PH~220V/440V/380/415V~50HZ/60HZ
Type Of Control:
Expansion Valve
Packages:
Plywood Case
Compressor Tpye:
Scroll Compressor
Original:
China
Highlight:

3HP Air Cooled Scroll Chiller

,

Air Cooled Scroll Chiller For Printing

,

Industrial Process Air Chillers

Payment & Shipping Terms
Minimum Order Quantity
1
Packaging Details
Plywood case
Delivery Time
30 days
Payment Terms
L/C, T/T
Product Description

Technical Parameter of Air-cooled scrolled Type Chiller

Model

Item

ACK-3
Nominal cooling capacity Kcal/h 7955
kw 8.5
Input power kw 3.2
Power supply 3PH~380V/50HZ
Refrigerant Type R22
Type of control Capillary
Compressor Type Hermetic scroll type
Power (kw) 2.64
Condenser Type

Finned copper tube+low noise outer

rotor fan

Power(kw) 0.19
Cooling air flow(m³/h) 3000
Evaporator Type Shell and tube
Chilled water flow (m³/h) 1.47
Tank volume(L) 20
Inlet/outlet pipe chiller(inch) 1
Water pump Power(KW) 0.37
Lift(m) 20
Safety protection compressor over temperature, over-current protection, high and low pressure protection, over -temperature protection ,flow switch protection,phase sequence or missing phase protection,exhaust overheating protection
Net weight kg 150
Dimension mm 1030*520*1185
 

Note: 1. Nominal cooling capacity is according to:

Inlet chilled fluid temperature: 17℃, Outlet chilled fluid temperature: 12℃

Inlet cooling air temperature: 30℃,Outlet cooling air temperature: 35℃

2. Working Range:

The temperature range of chilled fluid is from 5℃ to 35℃;

Temperature difference between inlet and outlet chilled fluid is from 3℃ to 8℃.

It is better to run the chiller while the ambient temperature at or below 35℃.

We reserve the right to modify the above dimensions or parameters without further notice.

 

Send your inquiry directly to us

Privacy Policy China Good Quality Industrial Water Chiller Supplier. Copyright © 2022-2025 Shenzhen Anges Machinery Co., Ltd . All Rights Reserved.