Brand Name: | ANGES |
Model Number: | HBC-50(F) |
Packaging Details: | Plywood case |
Payment Terms: | T/T, L/C |
50HP Chiller 50Ton Industrial Air Cooled Water Chiller For Injection Molding Machine Modular Air Cooled Scroll Chiller
AIR-COOLED SCROLL CHILLERS
Air-cooled industrial chillers from 3kw to 185kw equipped with world class components, including high efficiency scroll compressor. They use ambient air to cool the refrigerant to help keep your industrial processes running strong. Air-cooled chillers are stand-alone units and do not require any additional equipment to function.
Scroll chiller compressor
Air or water-cooled chillers
Used in small to medium cooling loads
Typically, available for capacity 3 – 52 Tr, 10 – 180 kw
Popular brand Copeland, Danfoss and Panasonic
Chiller can use one or more compressors which depends on chiller capacity
Variable speed compressor for optional
Chiller Specifications
Model |
HBC-50(F) | ||
nominal cooling capacity | kcal/h | 121191 | |
kw | 140.9 | ||
input power | kw | 39.52 | |
power supply | 3PH/380V/50HZ | ||
refrigerant | type | R410a | |
type of control | Expansion valve | ||
compressor | type | hermetic scroll | |
power(kw) | 32.4 | ||
condenser | type | finned copper tube + low noise outer rotor fan | |
cooling air flow(m3/h) | 50000 | ||
evaporator | type | Shell and tube | |
chilled fluid flow(m3/h) | 24.3 | ||
volume(L) | 620 | ||
inlet and outlet pipe diameter (inch) | 3 | ||
pump | power (kw) | 4 | |
flow rate(m3/h) | 32 | ||
lift(m) | 22 | ||
safety protection | compressor over temperature, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing | ||
weight | kg | 1450 | |
dimension | mm | 2350*1760*2100 |
Type of industrial chillers (Base on condenser type)
There're two major types of industrial chillers in use today, air-cooled chillers, water-cooled chillers.Both air-cooled and water-cooled chillers are mostly the same, the main difference is in how the refrigerant is cooled(Condenser is different).
1. Air-cooled chillers use ambient air (thru a cooling fan) to cool the refrigerant in cooing condenser and are a stand-alone units do not require any additional equipment to function.Easier for install and maintain than water-cooled systems.
2. The most common types of wate-cooled chillers use water from an external tower to cool the refrigerant in the condenser. Water-cooled chillers are generally more efficient than air-cooled chillers.
3. The air cooler chiller equipped with a cooling fan can run directly, water cooled chiller needs to install water tower and pump for operation.
Features of industrial chiller unit
1. Adopting high-efficiency and energy-saving compressors of world class grade brands, high-quality copper tube fin condensers and shell and tube evaporators, high cooling efficiency, stable performance, low noise and long service life.
2. The air chiller design is very compact and made of high-grade materials,easy for installation and maintenance.
3. Industrial chiller has high pressure, low pressure, overload, water level, phase sequence and other protections to ensure the safe operation of the chiller unit.
4. The scroll type chillers use precise digital temperature controller with LCD display, high temperature-control precision of ±1℃, convenient temperature setting and temperature reading is clear and intuitive.
5. The air cooled scroll type chiller water tank contains a floating ball automatic water replenishment device which is used to measure and control the water level, so as to effectively save time for customers and improve work efficiency.
Benefits of an industrial water chller
1. Industrial water chiller can reduce downtime and improve productivity
2. Chiller has accurate temperature control capability, the chilled water temperature can be accurate to ±0.1
3. Industrial chiller is usually closed-loop systems, which can save water through recirculation cooling
4. Water chiller applied in Plastic and Rubber industry.It can accurately control the molding temperature and shorten the molding cycle.
5. Decrease equipment depreciation and degradation to cut down on operating expenditures.
What we will do before chiller delivery?
1. After industrial chiller assembly, we will charge nitrogen for pressure maintaining testing for 24hrs, to check whether there is leakage in the chiller cooling system.
2. Drain the nitrogen,vacuum the chiller system and set up parameters, then power on chiller and charge refrigerant at the same time.
3. Debug and test the chiller unit.
4. After the chiller commissioning, cleaning and labelling chiller unit, then have pre-delivery inspection before packing with plywood cases to to ensure that the chiller can be in good condition during transit.
Brand Name: | ANGES |
Model Number: | HBC-50(F) |
Packaging Details: | Plywood case |
Payment Terms: | T/T, L/C |
50HP Chiller 50Ton Industrial Air Cooled Water Chiller For Injection Molding Machine Modular Air Cooled Scroll Chiller
AIR-COOLED SCROLL CHILLERS
Air-cooled industrial chillers from 3kw to 185kw equipped with world class components, including high efficiency scroll compressor. They use ambient air to cool the refrigerant to help keep your industrial processes running strong. Air-cooled chillers are stand-alone units and do not require any additional equipment to function.
Scroll chiller compressor
Air or water-cooled chillers
Used in small to medium cooling loads
Typically, available for capacity 3 – 52 Tr, 10 – 180 kw
Popular brand Copeland, Danfoss and Panasonic
Chiller can use one or more compressors which depends on chiller capacity
Variable speed compressor for optional
Chiller Specifications
Model |
HBC-50(F) | ||
nominal cooling capacity | kcal/h | 121191 | |
kw | 140.9 | ||
input power | kw | 39.52 | |
power supply | 3PH/380V/50HZ | ||
refrigerant | type | R410a | |
type of control | Expansion valve | ||
compressor | type | hermetic scroll | |
power(kw) | 32.4 | ||
condenser | type | finned copper tube + low noise outer rotor fan | |
cooling air flow(m3/h) | 50000 | ||
evaporator | type | Shell and tube | |
chilled fluid flow(m3/h) | 24.3 | ||
volume(L) | 620 | ||
inlet and outlet pipe diameter (inch) | 3 | ||
pump | power (kw) | 4 | |
flow rate(m3/h) | 32 | ||
lift(m) | 22 | ||
safety protection | compressor over temperature, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing | ||
weight | kg | 1450 | |
dimension | mm | 2350*1760*2100 |
Type of industrial chillers (Base on condenser type)
There're two major types of industrial chillers in use today, air-cooled chillers, water-cooled chillers.Both air-cooled and water-cooled chillers are mostly the same, the main difference is in how the refrigerant is cooled(Condenser is different).
1. Air-cooled chillers use ambient air (thru a cooling fan) to cool the refrigerant in cooing condenser and are a stand-alone units do not require any additional equipment to function.Easier for install and maintain than water-cooled systems.
2. The most common types of wate-cooled chillers use water from an external tower to cool the refrigerant in the condenser. Water-cooled chillers are generally more efficient than air-cooled chillers.
3. The air cooler chiller equipped with a cooling fan can run directly, water cooled chiller needs to install water tower and pump for operation.
Features of industrial chiller unit
1. Adopting high-efficiency and energy-saving compressors of world class grade brands, high-quality copper tube fin condensers and shell and tube evaporators, high cooling efficiency, stable performance, low noise and long service life.
2. The air chiller design is very compact and made of high-grade materials,easy for installation and maintenance.
3. Industrial chiller has high pressure, low pressure, overload, water level, phase sequence and other protections to ensure the safe operation of the chiller unit.
4. The scroll type chillers use precise digital temperature controller with LCD display, high temperature-control precision of ±1℃, convenient temperature setting and temperature reading is clear and intuitive.
5. The air cooled scroll type chiller water tank contains a floating ball automatic water replenishment device which is used to measure and control the water level, so as to effectively save time for customers and improve work efficiency.
Benefits of an industrial water chller
1. Industrial water chiller can reduce downtime and improve productivity
2. Chiller has accurate temperature control capability, the chilled water temperature can be accurate to ±0.1
3. Industrial chiller is usually closed-loop systems, which can save water through recirculation cooling
4. Water chiller applied in Plastic and Rubber industry.It can accurately control the molding temperature and shorten the molding cycle.
5. Decrease equipment depreciation and degradation to cut down on operating expenditures.
What we will do before chiller delivery?
1. After industrial chiller assembly, we will charge nitrogen for pressure maintaining testing for 24hrs, to check whether there is leakage in the chiller cooling system.
2. Drain the nitrogen,vacuum the chiller system and set up parameters, then power on chiller and charge refrigerant at the same time.
3. Debug and test the chiller unit.
4. After the chiller commissioning, cleaning and labelling chiller unit, then have pre-delivery inspection before packing with plywood cases to to ensure that the chiller can be in good condition during transit.