Send Message
Good price  online

products details

Home > Products >
Industrial Water Chiller
>
Air Cooled Industrial Water Chiller 15hp 15 Ton Scroll Type

Air Cooled Industrial Water Chiller 15hp 15 Ton Scroll Type

Brand Name: ANGES
Model Number: HBC-15
Packaging Details: Plywood case
Payment Terms: T/T, L/C
Detail Information
Place of Origin:
China
Type:
Air-cooled
Compressor Type:
Scroll Type
Capacity:
45.4 Kw, 15ton
Refrigerant:
R410a
Evaporator:
Shell And Tube
Condenser:
Finned Copper Tube+ Outer-rotor Fan
Voltage:
3PH~220V/380/415V~50HZ/60HZ
Condition:
Brandnew
Warranty:
12 Months
Application:
Industrial Cooling Solutions
Water Tank:
145L
Water Pump:
Included, 2-4bar
High Light:

Air Cooled Industrial Water Chiller

,

Industrial Water Chiller 15hp

,

15 Ton industrial chiller system

Product Description

Industrial Water Chiller 15hp Air Cooled Water Cooling System Chilling Equipment Scroll Type Water Chiller Lab Chiller

 

AIR-COOLED SCROLL CHILLERS
Air-cooled industrial chillers from 3kw to 185kw equipped with world class components, including high efficiency scroll compressor. They use ambient air to cool the refrigerant to help keep your industrial processes running strong. Air-cooled chillers are stand-alone units and do not require any additional equipment to function.

 

Water chiller Specifications

Model

HBC-15
nominal cooling capacity kcal/h 39044
  kw 45.4
input power kw 15.21
power supply 3PH/380V/50HZ
refrigerant type R410a
  type of control Expansion valve
compressor type hermetic scroll
  power(kw) 12.61
condenser type finned copper tube + low noise outer rotor fan
  cooling air flow(m3/h) 15000
evaporator type Shell and tube
  chilled fluid flow(m3/h) 7.83
  volume(L) 300
  inlet and outlet pipe diameter (inch) 2
pump power (kw) 1.5
  flow rate(m3/h)  
  lift(m) 20
safety protection compressor over temperature, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing
weight kg 750
dimension mm 1850*990*1780
 

Type of industrial chillers (Base on condenser type)

 

There're two major types of industrial chillers in use today, air-cooled chillers, water-cooled chillers.Both air-cooled and water-cooled chillers are mostly the same, the main difference is in how the refrigerant is cooled(Condenser is different).

 

1. Air-cooled chillers use ambient air (thru a cooling fan) to cool the refrigerant in cooing condenser and are a stand-alone units do not require any additional equipment to function.Easier for install and maintain than water-cooled systems.

2. The most common types of wate-cooled chillers use water from an external tower to cool the refrigerant in the condenser. Water-cooled chillers are generally more efficient than air-cooled chillers.

3. The air cooler chiller equipped with a cooling fan can run directly, water cooled chiller needs to install water tower and pump for operation.

 

Features of industrial chiller unit

 

1. The water chiller system innovative design and modern technology on the front provide higher cooling efficiency for your process.

2. The air chiller design is very compact and made of high-grade materials. It has stronger durability and longer service life.

3. Industrial chiller has high pressure, low pressure, overload, water level, phase sequence and other protections to ensure the safe operation of the chiller unit.

4. The chiller has a wide range of applications and can be used in the rubber and plastics industry, chemical industry, laser industry, etc.

5. Industrial water chiller is simple to operate, install and maintain

 

Benefit of industrial chiller applications

 

1. Provide constant temperature and constant water flow chilled water to the production line, to increased production speed and ensure efficiency production.

2. Accurate temperature control capability, the water temperature can be accurate to ±1℃, to ensure the highest quality final products.

3. The cooling fluid is recirculated to reduce waste and cost.

4. Water chiller systems prevent damage to heat-sensitive industrial components preventing undesirable repair downtime that might slow or even halt production altogether.

 

What we will do before chiller delivery ?


1. After industrial chiller assembly, we will charge nitrogen for pressure maintaining testing for 24hrs, to check whether there is leakage in the chiller cooling system.
2. Drain the nitrogen,vacuum the chiller system and set up parameters, then power on chiller and charge refrigerant at the same time.
3. Debug and test the chiller unit.
4. After the chiller commissioning, cleaning and labelling chiller unit, then have pre-delivery inspection before packing with plywood cases to to ensure that the chiller can be in good condition during transit.

 

How to select the model of the chiller ?

  1. We need to know the heat load of your process or chiller cooling capacity.
  2. Required water temperature, water pressure and flow rate.
  3.  Application and power supply in local.
  4. Max. Ambient temperature in summer day
  5. Customized special specifications are acceptable. Contact us for more chiller Specification by number +86 13923791048.

 

Air cooled industrial chiller installation and maintenance

 

Maintenance: Air-cooled chillers eliminate the need for cooling towers and no need water treatment, chiller condenser-tube cleaning, tower mechanical maintenance.

 

Installation: Most of the air-cooled chillers are packed systems which are including the air-cooled finned condenser, evaporator compressor and evaporator.Some of them are built-in water storage tank and pump,they are designed and configured at the factory for optimal performance and reliability, which reduces design and simplifies installation.

 

 

 

 

 

 

 

 


 
 

Products Details

Home > Products >
Industrial Water Chiller
>
Air Cooled Industrial Water Chiller 15hp 15 Ton Scroll Type

Air Cooled Industrial Water Chiller 15hp 15 Ton Scroll Type

Brand Name: ANGES
Model Number: HBC-15
Packaging Details: Plywood case
Payment Terms: T/T, L/C
Detail Information
Place of Origin:
China
Brand Name:
ANGES
Model Number:
HBC-15
Type:
Air-cooled
Compressor Type:
Scroll Type
Capacity:
45.4 Kw, 15ton
Refrigerant:
R410a
Evaporator:
Shell And Tube
Condenser:
Finned Copper Tube+ Outer-rotor Fan
Voltage:
3PH~220V/380/415V~50HZ/60HZ
Condition:
Brandnew
Warranty:
12 Months
Application:
Industrial Cooling Solutions
Water Tank:
145L
Water Pump:
Included, 2-4bar
Packaging Details:
Plywood case
Delivery Time:
10-35 days
Payment Terms:
T/T, L/C
High Light:

Air Cooled Industrial Water Chiller

,

Industrial Water Chiller 15hp

,

15 Ton industrial chiller system

Product Description

Industrial Water Chiller 15hp Air Cooled Water Cooling System Chilling Equipment Scroll Type Water Chiller Lab Chiller

 

AIR-COOLED SCROLL CHILLERS
Air-cooled industrial chillers from 3kw to 185kw equipped with world class components, including high efficiency scroll compressor. They use ambient air to cool the refrigerant to help keep your industrial processes running strong. Air-cooled chillers are stand-alone units and do not require any additional equipment to function.

 

Water chiller Specifications

Model

HBC-15
nominal cooling capacity kcal/h 39044
  kw 45.4
input power kw 15.21
power supply 3PH/380V/50HZ
refrigerant type R410a
  type of control Expansion valve
compressor type hermetic scroll
  power(kw) 12.61
condenser type finned copper tube + low noise outer rotor fan
  cooling air flow(m3/h) 15000
evaporator type Shell and tube
  chilled fluid flow(m3/h) 7.83
  volume(L) 300
  inlet and outlet pipe diameter (inch) 2
pump power (kw) 1.5
  flow rate(m3/h)  
  lift(m) 20
safety protection compressor over temperature, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing
weight kg 750
dimension mm 1850*990*1780
 

Type of industrial chillers (Base on condenser type)

 

There're two major types of industrial chillers in use today, air-cooled chillers, water-cooled chillers.Both air-cooled and water-cooled chillers are mostly the same, the main difference is in how the refrigerant is cooled(Condenser is different).

 

1. Air-cooled chillers use ambient air (thru a cooling fan) to cool the refrigerant in cooing condenser and are a stand-alone units do not require any additional equipment to function.Easier for install and maintain than water-cooled systems.

2. The most common types of wate-cooled chillers use water from an external tower to cool the refrigerant in the condenser. Water-cooled chillers are generally more efficient than air-cooled chillers.

3. The air cooler chiller equipped with a cooling fan can run directly, water cooled chiller needs to install water tower and pump for operation.

 

Features of industrial chiller unit

 

1. The water chiller system innovative design and modern technology on the front provide higher cooling efficiency for your process.

2. The air chiller design is very compact and made of high-grade materials. It has stronger durability and longer service life.

3. Industrial chiller has high pressure, low pressure, overload, water level, phase sequence and other protections to ensure the safe operation of the chiller unit.

4. The chiller has a wide range of applications and can be used in the rubber and plastics industry, chemical industry, laser industry, etc.

5. Industrial water chiller is simple to operate, install and maintain

 

Benefit of industrial chiller applications

 

1. Provide constant temperature and constant water flow chilled water to the production line, to increased production speed and ensure efficiency production.

2. Accurate temperature control capability, the water temperature can be accurate to ±1℃, to ensure the highest quality final products.

3. The cooling fluid is recirculated to reduce waste and cost.

4. Water chiller systems prevent damage to heat-sensitive industrial components preventing undesirable repair downtime that might slow or even halt production altogether.

 

What we will do before chiller delivery ?


1. After industrial chiller assembly, we will charge nitrogen for pressure maintaining testing for 24hrs, to check whether there is leakage in the chiller cooling system.
2. Drain the nitrogen,vacuum the chiller system and set up parameters, then power on chiller and charge refrigerant at the same time.
3. Debug and test the chiller unit.
4. After the chiller commissioning, cleaning and labelling chiller unit, then have pre-delivery inspection before packing with plywood cases to to ensure that the chiller can be in good condition during transit.

 

How to select the model of the chiller ?

  1. We need to know the heat load of your process or chiller cooling capacity.
  2. Required water temperature, water pressure and flow rate.
  3.  Application and power supply in local.
  4. Max. Ambient temperature in summer day
  5. Customized special specifications are acceptable. Contact us for more chiller Specification by number +86 13923791048.

 

Air cooled industrial chiller installation and maintenance

 

Maintenance: Air-cooled chillers eliminate the need for cooling towers and no need water treatment, chiller condenser-tube cleaning, tower mechanical maintenance.

 

Installation: Most of the air-cooled chillers are packed systems which are including the air-cooled finned condenser, evaporator compressor and evaporator.Some of them are built-in water storage tank and pump,they are designed and configured at the factory for optimal performance and reliability, which reduces design and simplifies installation.