Brand Name: | ANGES |
Model Number: | HBC-15 |
Packaging Details: | Plywood case |
Payment Terms: | T/T, L/C |
Industrial Water Chiller 15hp Air Cooled Water Cooling System Chilling Equipment Scroll Type Water Chiller Lab Chiller
AIR-COOLED SCROLL CHILLERS
Air-cooled industrial chillers from 3kw to 185kw equipped with world class components, including high efficiency scroll compressor. They use ambient air to cool the refrigerant to help keep your industrial processes running strong. Air-cooled chillers are stand-alone units and do not require any additional equipment to function.
Model |
HBC-15 | ||
nominal cooling capacity | kcal/h | 39044 | |
kw | 45.4 | ||
input power | kw | 15.21 | |
power supply | 3PH/380V/50HZ | ||
refrigerant | type | R410a | |
type of control | Expansion valve | ||
compressor | type | hermetic scroll | |
power(kw) | 12.61 | ||
condenser | type | finned copper tube + low noise outer rotor fan | |
cooling air flow(m3/h) | 15000 | ||
evaporator | type | Shell and tube | |
chilled fluid flow(m3/h) | 7.83 | ||
volume(L) | 300 | ||
inlet and outlet pipe diameter (inch) | 2 | ||
pump | power (kw) | 1.5 | |
flow rate(m3/h) | |||
lift(m) | 20 | ||
safety protection | compressor over temperature, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing | ||
weight | kg | 750 | |
dimension | mm | 1850*990*1780 |
Type of industrial chillers (Base on condenser type)
There're two major types of industrial chillers in use today, air-cooled chillers, water-cooled chillers.Both air-cooled and water-cooled chillers are mostly the same, the main difference is in how the refrigerant is cooled(Condenser is different).
1. Air-cooled chillers use ambient air (thru a cooling fan) to cool the refrigerant in cooing condenser and are a stand-alone units do not require any additional equipment to function.Easier for install and maintain than water-cooled systems.
2. The most common types of wate-cooled chillers use water from an external tower to cool the refrigerant in the condenser. Water-cooled chillers are generally more efficient than air-cooled chillers.
3. The air cooler chiller equipped with a cooling fan can run directly, water cooled chiller needs to install water tower and pump for operation.
Features of industrial chiller unit
1. The water chiller system innovative design and modern technology on the front provide higher cooling efficiency for your process.
2. The air chiller design is very compact and made of high-grade materials. It has stronger durability and longer service life.
3. Industrial chiller has high pressure, low pressure, overload, water level, phase sequence and other protections to ensure the safe operation of the chiller unit.
4. The chiller has a wide range of applications and can be used in the rubber and plastics industry, chemical industry, laser industry, etc.
5. Industrial water chiller is simple to operate, install and maintain
Benefit of industrial chiller applications
1. Provide constant temperature and constant water flow chilled water to the production line, to increased production speed and ensure efficiency production.
2. Accurate temperature control capability, the water temperature can be accurate to ±1℃, to ensure the highest quality final products.
3. The cooling fluid is recirculated to reduce waste and cost.
4. Water chiller systems prevent damage to heat-sensitive industrial components preventing undesirable repair downtime that might slow or even halt production altogether.
What we will do before chiller delivery ?
1. After industrial chiller assembly, we will charge nitrogen for pressure maintaining testing for 24hrs, to check whether there is leakage in the chiller cooling system.
2. Drain the nitrogen,vacuum the chiller system and set up parameters, then power on chiller and charge refrigerant at the same time.
3. Debug and test the chiller unit.
4. After the chiller commissioning, cleaning and labelling chiller unit, then have pre-delivery inspection before packing with plywood cases to to ensure that the chiller can be in good condition during transit.
How to select the model of the chiller ?
Air cooled industrial chiller installation and maintenance
Maintenance: Air-cooled chillers eliminate the need for cooling towers and no need water treatment, chiller condenser-tube cleaning, tower mechanical maintenance.
Installation: Most of the air-cooled chillers are packed systems which are including the air-cooled finned condenser, evaporator compressor and evaporator.Some of them are built-in water storage tank and pump,they are designed and configured at the factory for optimal performance and reliability, which reduces design and simplifies installation.
Brand Name: | ANGES |
Model Number: | HBC-15 |
Packaging Details: | Plywood case |
Payment Terms: | T/T, L/C |
Industrial Water Chiller 15hp Air Cooled Water Cooling System Chilling Equipment Scroll Type Water Chiller Lab Chiller
AIR-COOLED SCROLL CHILLERS
Air-cooled industrial chillers from 3kw to 185kw equipped with world class components, including high efficiency scroll compressor. They use ambient air to cool the refrigerant to help keep your industrial processes running strong. Air-cooled chillers are stand-alone units and do not require any additional equipment to function.
Model |
HBC-15 | ||
nominal cooling capacity | kcal/h | 39044 | |
kw | 45.4 | ||
input power | kw | 15.21 | |
power supply | 3PH/380V/50HZ | ||
refrigerant | type | R410a | |
type of control | Expansion valve | ||
compressor | type | hermetic scroll | |
power(kw) | 12.61 | ||
condenser | type | finned copper tube + low noise outer rotor fan | |
cooling air flow(m3/h) | 15000 | ||
evaporator | type | Shell and tube | |
chilled fluid flow(m3/h) | 7.83 | ||
volume(L) | 300 | ||
inlet and outlet pipe diameter (inch) | 2 | ||
pump | power (kw) | 1.5 | |
flow rate(m3/h) | |||
lift(m) | 20 | ||
safety protection | compressor over temperature, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing | ||
weight | kg | 750 | |
dimension | mm | 1850*990*1780 |
Type of industrial chillers (Base on condenser type)
There're two major types of industrial chillers in use today, air-cooled chillers, water-cooled chillers.Both air-cooled and water-cooled chillers are mostly the same, the main difference is in how the refrigerant is cooled(Condenser is different).
1. Air-cooled chillers use ambient air (thru a cooling fan) to cool the refrigerant in cooing condenser and are a stand-alone units do not require any additional equipment to function.Easier for install and maintain than water-cooled systems.
2. The most common types of wate-cooled chillers use water from an external tower to cool the refrigerant in the condenser. Water-cooled chillers are generally more efficient than air-cooled chillers.
3. The air cooler chiller equipped with a cooling fan can run directly, water cooled chiller needs to install water tower and pump for operation.
Features of industrial chiller unit
1. The water chiller system innovative design and modern technology on the front provide higher cooling efficiency for your process.
2. The air chiller design is very compact and made of high-grade materials. It has stronger durability and longer service life.
3. Industrial chiller has high pressure, low pressure, overload, water level, phase sequence and other protections to ensure the safe operation of the chiller unit.
4. The chiller has a wide range of applications and can be used in the rubber and plastics industry, chemical industry, laser industry, etc.
5. Industrial water chiller is simple to operate, install and maintain
Benefit of industrial chiller applications
1. Provide constant temperature and constant water flow chilled water to the production line, to increased production speed and ensure efficiency production.
2. Accurate temperature control capability, the water temperature can be accurate to ±1℃, to ensure the highest quality final products.
3. The cooling fluid is recirculated to reduce waste and cost.
4. Water chiller systems prevent damage to heat-sensitive industrial components preventing undesirable repair downtime that might slow or even halt production altogether.
What we will do before chiller delivery ?
1. After industrial chiller assembly, we will charge nitrogen for pressure maintaining testing for 24hrs, to check whether there is leakage in the chiller cooling system.
2. Drain the nitrogen,vacuum the chiller system and set up parameters, then power on chiller and charge refrigerant at the same time.
3. Debug and test the chiller unit.
4. After the chiller commissioning, cleaning and labelling chiller unit, then have pre-delivery inspection before packing with plywood cases to to ensure that the chiller can be in good condition during transit.
How to select the model of the chiller ?
Air cooled industrial chiller installation and maintenance
Maintenance: Air-cooled chillers eliminate the need for cooling towers and no need water treatment, chiller condenser-tube cleaning, tower mechanical maintenance.
Installation: Most of the air-cooled chillers are packed systems which are including the air-cooled finned condenser, evaporator compressor and evaporator.Some of them are built-in water storage tank and pump,they are designed and configured at the factory for optimal performance and reliability, which reduces design and simplifies installation.