Brand Name: ANGES
Model Number: 6hp
MOQ: 1
Packaging Details: Plywood case
Payment Terms: L/C, T/T
Detail Information
Place of Origin:
China
Voltage:
3PH~220V/380V/415V~50HZ/60HZ
Capacity:
17.1kw
Weight:
200kg
Pump:
2 Bar
Refrigerant:
R22/R407C/R410A/R134a
Fan Power:
0.38kw
Compressor Tpye:
Scroll Compressor
Water Tank Material:
Stainless Steel
Evaporator:
Shell And Tube
Compressor Type Type:
Scroll
Highlight:

6HP Air Cooled Scroll Chiller

,

Industrial Air Cooled Scroll Chiller

,

Industrial Process Air Chillers

Product Description

Technical Parameter of Air-cooled scrolled Type Chiller

Model

Item

ACK-6
Nominal cooling capacity Kcal/h 14706
kw 17.1
Input power kw 5.93
Power supply 3PH~380V/50HZ
Refrigerant Type R22
Type of control Capillary
Compressor Type Hermetic scroll type
Power (kw) 4.8
Condenser Type

Finned copper tube+low noise outer

rotor fan

Power(kw) 0.38
Cooling air flow(m3/h) 6000
Evaporator type Shell and tube
Chilled water flow (m³/h) 2.95
Tank volume(L) 30
Inlet/outlet pipe chiller(inch) 1
Water pump Power(KW) 0.75
Lift(m) 20
Safety protection compressor over temperature, over-current protection, high and low pressure protection, over -temperature protection ,flow switch protection,phase sequence or missing phase protection,exhaust overheating protection
Net weight kg 200
Dimension mm 1140*560*1250
 

Note: 1. Nominal cooling capacity is according to:

Inlet chilled fluid temperature: 17℃, Outlet chilled fluid temperature: 12℃

Inlet cooling air temperature: 30℃,Outlet cooling air temperature: 35℃

2. Working Range:

The temperature range of chilled fluid is from 5℃ to 35℃;

Temperature difference between inlet and outlet chilled fluid is from 3℃ to 8℃.

It is better to run the chiller while the ambient temperature at or below 35℃.

We reserve the right to modify the above dimensions or parameters without further notice.

Products Details

Home > Products >
Industrial Water Chiller
>
6HP Air Cooled Scroll Chiller Industrial Process Air Chillers For Printing And BOPP Film Lamination Line

6HP Air Cooled Scroll Chiller Industrial Process Air Chillers For Printing And BOPP Film Lamination Line

Brand Name: ANGES
Model Number: 6hp
MOQ: 1
Packaging Details: Plywood case
Payment Terms: L/C, T/T
Detail Information
Place of Origin:
China
Brand Name:
ANGES
Model Number:
6hp
Voltage:
3PH~220V/380V/415V~50HZ/60HZ
Capacity:
17.1kw
Weight:
200kg
Pump:
2 Bar
Refrigerant:
R22/R407C/R410A/R134a
Fan Power:
0.38kw
Compressor Tpye:
Scroll Compressor
Water Tank Material:
Stainless Steel
Evaporator:
Shell And Tube
Compressor Type Type:
Scroll
Minimum Order Quantity:
1
Packaging Details:
Plywood case
Delivery Time:
25 days
Payment Terms:
L/C, T/T
Highlight:

6HP Air Cooled Scroll Chiller

,

Industrial Air Cooled Scroll Chiller

,

Industrial Process Air Chillers

Product Description

Technical Parameter of Air-cooled scrolled Type Chiller

Model

Item

ACK-6
Nominal cooling capacity Kcal/h 14706
kw 17.1
Input power kw 5.93
Power supply 3PH~380V/50HZ
Refrigerant Type R22
Type of control Capillary
Compressor Type Hermetic scroll type
Power (kw) 4.8
Condenser Type

Finned copper tube+low noise outer

rotor fan

Power(kw) 0.38
Cooling air flow(m3/h) 6000
Evaporator type Shell and tube
Chilled water flow (m³/h) 2.95
Tank volume(L) 30
Inlet/outlet pipe chiller(inch) 1
Water pump Power(KW) 0.75
Lift(m) 20
Safety protection compressor over temperature, over-current protection, high and low pressure protection, over -temperature protection ,flow switch protection,phase sequence or missing phase protection,exhaust overheating protection
Net weight kg 200
Dimension mm 1140*560*1250
 

Note: 1. Nominal cooling capacity is according to:

Inlet chilled fluid temperature: 17℃, Outlet chilled fluid temperature: 12℃

Inlet cooling air temperature: 30℃,Outlet cooling air temperature: 35℃

2. Working Range:

The temperature range of chilled fluid is from 5℃ to 35℃;

Temperature difference between inlet and outlet chilled fluid is from 3℃ to 8℃.

It is better to run the chiller while the ambient temperature at or below 35℃.