Brand Name: | ANGES |
Model Number: | 25hp |
MOQ: | 1 |
Payment Terms: | L/C, T/T |
Model Item |
ACK-25(D) | |
Nominal cooling capacity | Kcal/h | 60028 |
kw | 73.2 | |
Input power | kw | 22.36 |
Power supply | 3PH~3800V/60HZ | |
Refrigerant | Type | R22 |
Type of control | Expansion valve | |
Compressor | Type | Hermetic scroll type |
Power (kw) | 18.6 | |
Condenser | Type |
Finned copper tube+low noise outer rotor fan |
Power(kw) | 1.56 | |
Cooling air flow(m3 /h) | 25000 | |
Evaporator | type | Shell and tube |
Chilled water flow(m3 /h) | 12.62 | |
Tank volume(L) | 170 | |
Inlet/outlet pipe chiller(inch) | 2-1/2 | |
Water pump | Power(kw) | 2.2 |
Lift(m) | 20 | |
Safety protection | compressor over temperature, over-current protection, high and low pressure protection, over -temperature protection ,flow switch protection,phase sequence or missing phase protection,exhaust overheating protection | |
Net weight | kg | 1100 |
Dimension | mm | 2200*1130*2000 |
Note: 1. Nominal cooling capacity is according to:
Inlet chilled fluid temperature: 17℃, Outlet chilled fluid temperature: 12℃
Inlet cooling air temperature: 30℃,Outlet cooling air temperature: 35℃
2. Working Range:
The temperature range of chilled fluid is from 5℃ to 35℃;
Temperature difference between inlet and outlet chilled fluid is from 3℃ to 8℃.
It is better to run the chiller while the ambient temperature at or below 35℃.
We reserve the right to modify the above dimensions or parameters without further notice.
Brand Name: | ANGES |
Model Number: | 25hp |
MOQ: | 1 |
Payment Terms: | L/C, T/T |
Model Item |
ACK-25(D) | |
Nominal cooling capacity | Kcal/h | 60028 |
kw | 73.2 | |
Input power | kw | 22.36 |
Power supply | 3PH~3800V/60HZ | |
Refrigerant | Type | R22 |
Type of control | Expansion valve | |
Compressor | Type | Hermetic scroll type |
Power (kw) | 18.6 | |
Condenser | Type |
Finned copper tube+low noise outer rotor fan |
Power(kw) | 1.56 | |
Cooling air flow(m3 /h) | 25000 | |
Evaporator | type | Shell and tube |
Chilled water flow(m3 /h) | 12.62 | |
Tank volume(L) | 170 | |
Inlet/outlet pipe chiller(inch) | 2-1/2 | |
Water pump | Power(kw) | 2.2 |
Lift(m) | 20 | |
Safety protection | compressor over temperature, over-current protection, high and low pressure protection, over -temperature protection ,flow switch protection,phase sequence or missing phase protection,exhaust overheating protection | |
Net weight | kg | 1100 |
Dimension | mm | 2200*1130*2000 |
Note: 1. Nominal cooling capacity is according to:
Inlet chilled fluid temperature: 17℃, Outlet chilled fluid temperature: 12℃
Inlet cooling air temperature: 30℃,Outlet cooling air temperature: 35℃
2. Working Range:
The temperature range of chilled fluid is from 5℃ to 35℃;
Temperature difference between inlet and outlet chilled fluid is from 3℃ to 8℃.
It is better to run the chiller while the ambient temperature at or below 35℃.
We reserve the right to modify the above dimensions or parameters without further notice.