Brand Name: | ANGES |
Model Number: | ACK-5 |
MOQ: | 1 |
Price: | Negotiation |
Packaging Details: | Plywood case |
Payment Terms: | T/T, L/C |
2ton industrial chiller units for Industrial process cooling machince 5hp air cooled chiller unit
Product Description for 5HP 2ton 14.9kw Industrial Air Cooled Scroll Glycol Water Chiller for Brewery Fermenting Tanks for Beverage Milk Cooling System with 5 main components including compressor, condenser, condenser fans, expansion valvue, evaporator
Injection Molding Chiller Specification
Model |
ACK-5 | |
Nominal cooling capacity | Kcal/h | 12857 |
kw | 14.95 | |
Input power | kw | 5.6 |
Power supply | 3PH/380V/50HZ | |
Refrigerant | Type | R22 |
Type of control | Expansion valve | |
Compressor | Type | Hermetic scroll type |
Power (kw) | 4.47 | |
Condenser | Type |
Finned copper tube+low noise outer rotor fan |
Fan | Power(kw) | 0.38 |
Cooling air flow | 5000 | |
Evaporator | Type | Shell and tube |
Chilled water flow | 3 | |
Tank volume(L) | 30 | |
Inlet/outlet pipe chiller( inch) | 1-1/2 | |
Water pump | Power(KW) | 0.75 |
Lift(m) | 20 | |
Safety protection | compressor over temperature, over-current protection, high and low pressure protection, over -temperature protection ,flow switch protection,phase sequence or missing phase protection,exhaust overheating protection | |
Net weight | kg | 180 |
Dimension | mm | 1140*560*1050 |
Anges chiller Application Range
FAQ
1.How does a chiller system work?
Chiller has two circulation,one is process water circulation,the other is refrigerant gas circulation.Heat picked up from the process.Heat transfers to refrigerant circulation.Heat is remove to air or water.
2.How to calculate cooling capacity for chillers?
Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-t2)/0.86
Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)
3.How can we do for chiller maintenance ?
Step 1: Keep Tubes Clean
Step 2: Ensure a Leak-free Unit
Step 3: Sustain Proper Water Treatment(prevent scale, corrosion)
Step 4: Analyze Oil and Refrigerant
Brand Name: | ANGES |
Model Number: | ACK-5 |
MOQ: | 1 |
Price: | Negotiation |
Packaging Details: | Plywood case |
Payment Terms: | T/T, L/C |
2ton industrial chiller units for Industrial process cooling machince 5hp air cooled chiller unit
Product Description for 5HP 2ton 14.9kw Industrial Air Cooled Scroll Glycol Water Chiller for Brewery Fermenting Tanks for Beverage Milk Cooling System with 5 main components including compressor, condenser, condenser fans, expansion valvue, evaporator
Injection Molding Chiller Specification
Model |
ACK-5 | |
Nominal cooling capacity | Kcal/h | 12857 |
kw | 14.95 | |
Input power | kw | 5.6 |
Power supply | 3PH/380V/50HZ | |
Refrigerant | Type | R22 |
Type of control | Expansion valve | |
Compressor | Type | Hermetic scroll type |
Power (kw) | 4.47 | |
Condenser | Type |
Finned copper tube+low noise outer rotor fan |
Fan | Power(kw) | 0.38 |
Cooling air flow | 5000 | |
Evaporator | Type | Shell and tube |
Chilled water flow | 3 | |
Tank volume(L) | 30 | |
Inlet/outlet pipe chiller( inch) | 1-1/2 | |
Water pump | Power(KW) | 0.75 |
Lift(m) | 20 | |
Safety protection | compressor over temperature, over-current protection, high and low pressure protection, over -temperature protection ,flow switch protection,phase sequence or missing phase protection,exhaust overheating protection | |
Net weight | kg | 180 |
Dimension | mm | 1140*560*1050 |
Anges chiller Application Range
FAQ
1.How does a chiller system work?
Chiller has two circulation,one is process water circulation,the other is refrigerant gas circulation.Heat picked up from the process.Heat transfers to refrigerant circulation.Heat is remove to air or water.
2.How to calculate cooling capacity for chillers?
Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-t2)/0.86
Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)
3.How can we do for chiller maintenance ?
Step 1: Keep Tubes Clean
Step 2: Ensure a Leak-free Unit
Step 3: Sustain Proper Water Treatment(prevent scale, corrosion)
Step 4: Analyze Oil and Refrigerant