Brand Name: | ANGES |
Model Number: | ACK-50(F) |
Price: | Negotiation |
Packaging Details: | Plywood case |
Payment Terms: | T/T, L/C |
Product Description for 30HP 30ton 92.4kw Industrial Air Cooled Scroll Glycol Water Chiller for Brewery Fermenting Tanks for Beverage Milk Cooling System with CE
Injection Molding Chiller Specification
Model Item |
ACK-30(D) | |
Nominal cooling capacity | Kcal/h | 76024 |
kw | 92.4 | |
Input power | kw | 30.76 |
Power supply | 3PH~220V/60HZ | |
Refrigerant | Type | R22 |
Type of control | Expansion valve | |
Compressor | Type | Hermetic scroll type |
Power (kw) | 24.92 | |
Condenser | Type |
Finned copper tube+low noise outer rotor fan |
Power(kw) | 1.84 | |
Cooling air flow(m3 /h) | 30000 | |
Evaporator | type | Shell and tube |
Chilled water flow(m3 /h) | 15.93 | |
Tank volume(L) | 220 | |
Inlet/outlet pipe chiller(inch) | 2-1/2 | |
Water pump | Power(kw) | 4 |
Lift(m) | 22 | |
Safety protection | compressor over temperature, over-current protection, high and low pressure protection, over -temperature protection ,flow switch protection,phase sequence or missing phase protection,exhaust overheating protection | |
Net weight | kg | 1300 |
Dimension | mm | 2000*1480*1950 |
Anges chiller Application Range.
Benefit of Plastic Process Chiller Applications
How to select the model of the chiller ?
1. We need to know the heat load of your process or chiller cooling capacity, it can be calculated roughly according to production capacity.
2. Required water temperature, water pressure and flow rate.
3. Application and power supply in local.
4. Max. Ambient temperature in summer day
5. Customized special specifications are acceptable. Contact us for more chiller Specification by number +86 13923791048.
FAQ
Brand Name: | ANGES |
Model Number: | ACK-50(F) |
Price: | Negotiation |
Packaging Details: | Plywood case |
Payment Terms: | T/T, L/C |
Product Description for 30HP 30ton 92.4kw Industrial Air Cooled Scroll Glycol Water Chiller for Brewery Fermenting Tanks for Beverage Milk Cooling System with CE
Injection Molding Chiller Specification
Model Item |
ACK-30(D) | |
Nominal cooling capacity | Kcal/h | 76024 |
kw | 92.4 | |
Input power | kw | 30.76 |
Power supply | 3PH~220V/60HZ | |
Refrigerant | Type | R22 |
Type of control | Expansion valve | |
Compressor | Type | Hermetic scroll type |
Power (kw) | 24.92 | |
Condenser | Type |
Finned copper tube+low noise outer rotor fan |
Power(kw) | 1.84 | |
Cooling air flow(m3 /h) | 30000 | |
Evaporator | type | Shell and tube |
Chilled water flow(m3 /h) | 15.93 | |
Tank volume(L) | 220 | |
Inlet/outlet pipe chiller(inch) | 2-1/2 | |
Water pump | Power(kw) | 4 |
Lift(m) | 22 | |
Safety protection | compressor over temperature, over-current protection, high and low pressure protection, over -temperature protection ,flow switch protection,phase sequence or missing phase protection,exhaust overheating protection | |
Net weight | kg | 1300 |
Dimension | mm | 2000*1480*1950 |
Anges chiller Application Range.
Benefit of Plastic Process Chiller Applications
How to select the model of the chiller ?
1. We need to know the heat load of your process or chiller cooling capacity, it can be calculated roughly according to production capacity.
2. Required water temperature, water pressure and flow rate.
3. Application and power supply in local.
4. Max. Ambient temperature in summer day
5. Customized special specifications are acceptable. Contact us for more chiller Specification by number +86 13923791048.
FAQ