5ton industrial chiller units for Industrial process cooling machince 5hp air cooled chiller unit
Product Description for 10HP 10ton 29kw Industrial Air Cooled Scroll Glycol Water Chiller for Brewery Fermenting Tanks for Beverage Milk Cooling System with CE
Product Name: Industrial air coolef scroll type chiller
Cooling capacity: 13kw/5hp
Output temp. :5-35C
Power supply: 3PH/220V, 380-415V, 440V-460V/50Hz or 60Hz;
Color: grey or customized
Refrigerant: R22/R407C/R134a/R410a
Compressor:Hermetic scroll type,world famous brand compressors from Copland, Panasonic etc
Injection Molding Chiller Specification
Model Item |
ACK-5 | |
Nominal cooling capacity | Kcal/h | 12857 |
kw | 14.95 | |
Input power | kw | 5.6 |
Power supply | 3PH/380V/50HZ | |
Refrigerant | Type | R22 |
Type of control | Expansion valve | |
Compressor | Type | Hermetic scroll type |
Power (kw) | 4.47 | |
Condenser | Type |
Finned copper tube+low noise outer rotor fan |
Fan | Power(kw) | 0.38 |
Cooling air flow | 5000 | |
Evaporator | Type | Shell and tube |
Chilled water flow | 3 | |
Tank volume(L) | 30 | |
Inlet/outlet pipe chiller( inch) | 1-1/2 | |
Water pump | Power(KW) | 0.75 |
Lift(m) | 20 | |
Safety protection | compressor over temperature, over-current protection, high and low pressure protection, over -temperature protection ,flow switch protection,phase sequence or missing phase protection,exhaust overheating protection | |
Net weight | kg | 180 |
Dimension | mm | 1140*560*1050 |
Anges chiller Application Range.
THE AFTER-SALE SERVICE OF ANGES CHILLER!
FAQ
1.How does a chiller system work?
Chiller has two circulation,one is process water circulation,the other is refrigerant gas circulation.Heat picked up from the process.Heat transfers to refrigerant circulation.Heat is remove to air or water.
2.How to calculate cooling capacity for chillers?
Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-t2)/0.86
Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)
3.How can we do for chiller maintenance ?
Step 1: Keep Tubes Clean
Step 2: Ensure a Leak-free Unit
Step 3: Sustain Proper Water Treatment(prevent scale, corrosion)
Step 4: Analyze Oil and Refrigerant
Brand Name: | ANGES |
Model Number: | ACK-5 |
Price: | Negotiation |
Packaging Details: | Plywood case |
Payment Terms: | T/T, L/C |
5ton industrial chiller units for Industrial process cooling machince 5hp air cooled chiller unit
Product Description for 10HP 10ton 29kw Industrial Air Cooled Scroll Glycol Water Chiller for Brewery Fermenting Tanks for Beverage Milk Cooling System with CE
Product Name: Industrial air coolef scroll type chiller
Cooling capacity: 13kw/5hp
Output temp. :5-35C
Power supply: 3PH/220V, 380-415V, 440V-460V/50Hz or 60Hz;
Color: grey or customized
Refrigerant: R22/R407C/R134a/R410a
Compressor:Hermetic scroll type,world famous brand compressors from Copland, Panasonic etc
Injection Molding Chiller Specification
Model Item |
ACK-5 | |
Nominal cooling capacity | Kcal/h | 12857 |
kw | 14.95 | |
Input power | kw | 5.6 |
Power supply | 3PH/380V/50HZ | |
Refrigerant | Type | R22 |
Type of control | Expansion valve | |
Compressor | Type | Hermetic scroll type |
Power (kw) | 4.47 | |
Condenser | Type |
Finned copper tube+low noise outer rotor fan |
Fan | Power(kw) | 0.38 |
Cooling air flow | 5000 | |
Evaporator | Type | Shell and tube |
Chilled water flow | 3 | |
Tank volume(L) | 30 | |
Inlet/outlet pipe chiller( inch) | 1-1/2 | |
Water pump | Power(KW) | 0.75 |
Lift(m) | 20 | |
Safety protection | compressor over temperature, over-current protection, high and low pressure protection, over -temperature protection ,flow switch protection,phase sequence or missing phase protection,exhaust overheating protection | |
Net weight | kg | 180 |
Dimension | mm | 1140*560*1050 |
Anges chiller Application Range.
THE AFTER-SALE SERVICE OF ANGES CHILLER!
FAQ
1.How does a chiller system work?
Chiller has two circulation,one is process water circulation,the other is refrigerant gas circulation.Heat picked up from the process.Heat transfers to refrigerant circulation.Heat is remove to air or water.
2.How to calculate cooling capacity for chillers?
Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-t2)/0.86
Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)
3.How can we do for chiller maintenance ?
Step 1: Keep Tubes Clean
Step 2: Ensure a Leak-free Unit
Step 3: Sustain Proper Water Treatment(prevent scale, corrosion)
Step 4: Analyze Oil and Refrigerant