Brand Name: | ANGES |
Model Number: | HBC-40(F) |
MOQ: | 1 |
Packaging Details: | Plywood case |
Payment Terms: | T/T, L/C |
40Ton Air Cooled Portable Water Chiller Modular Chiller 40 Ton Air Cooled Modular Chiller System Hvac Cool Water Chiller
Air cooled chillers are refrigeration systems that cool fluids and work in tandem with the air handler system of a facility. Air cooled chillers are types of chillers that rely on the use of fans to reject heat outside the building rather than relying on cooling towers.
Air-cooled Modular Chiller Specifications:
Model |
HBC-40(F) |
||
nominal cooling capacity |
kcal/h |
104920 |
|
kw |
122 |
||
input power |
kw |
39.2 |
|
power supply |
3PH/380V/50HZ |
||
refrigerant |
type |
R410a/R407C/R134A/ |
|
type of control |
Expansion valve |
||
compressor |
type |
hermetic scroll |
|
power(kw) |
32.4 |
||
condenser |
type |
finned copper tube + low noise outer rotor fan |
|
cooling air flow(m3/h) |
40000 |
||
evaporator |
type |
Shell and tube |
|
chilled fluid flow(m3/h) |
21.03 |
||
volume(L) |
580 |
||
inlet and outlet pipe diameter (inch) |
2-1/2 |
||
pump |
power (kw) |
4 |
|
flow rate(m3/h) |
25 |
||
Bar |
4 |
||
safety protection |
compressor over temperature, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing |
||
weight |
kg |
1250 |
|
dimension |
mm |
2100*1660*2100 |
Some distinctive features of Air-cooled Chiller
1. Low installation cost. The central screw chiller system includes refrigeration loops, reservoirs, pumps, and components required for multiple processes to work throughout the plant, with fewer piping installations.
2. Convenient installation and maintenance. This air cooling center does not require the installation of cooling towers, as well as water treatment, water cooler condenser tube cleaning, cooling tower machinery maintenance.
3. Accurate temperature control ability. The freezing temperature can be accurate to ±1℃ to ensure the highest quality of the final product.
4. High efficiency. The central chiller system continuously measures environmental and process conditions and will adjust to operate in the most efficient manner.
Benefit of industrial chiller applications
1. The ability to maintain constant and precise control of the process temperature.
2. The cooling fluid can be delivered directly to the application heat source to increased production speed and ensure efficiency production
3. Accurate temperature control capability, to ensure the highest quality final products.
4. Water chiller systems prevent damage to heat-sensitive industrial components preventing undesirable repair downtime that might slow or even halt production altogether.
Air cooled industrial chiller installation and maintenance
Maintenance: Air cooled chiller does not need cooling tower, does not need water treatment, chiller condensate pipe cleaning, tower mechanical maintenance.
Installation: Most air-cooled chiller units are combined systems, including air-cooled fin condenser, evaporator compressor and evaporator. Some of these are built-in water storage tanks and pumps, which are designed and configured in the factory for optimum performance and reliability, which reduces design and simplifies installation.
Brand Name: | ANGES |
Model Number: | HBC-40(F) |
MOQ: | 1 |
Packaging Details: | Plywood case |
Payment Terms: | T/T, L/C |
40Ton Air Cooled Portable Water Chiller Modular Chiller 40 Ton Air Cooled Modular Chiller System Hvac Cool Water Chiller
Air cooled chillers are refrigeration systems that cool fluids and work in tandem with the air handler system of a facility. Air cooled chillers are types of chillers that rely on the use of fans to reject heat outside the building rather than relying on cooling towers.
Air-cooled Modular Chiller Specifications:
Model |
HBC-40(F) |
||
nominal cooling capacity |
kcal/h |
104920 |
|
kw |
122 |
||
input power |
kw |
39.2 |
|
power supply |
3PH/380V/50HZ |
||
refrigerant |
type |
R410a/R407C/R134A/ |
|
type of control |
Expansion valve |
||
compressor |
type |
hermetic scroll |
|
power(kw) |
32.4 |
||
condenser |
type |
finned copper tube + low noise outer rotor fan |
|
cooling air flow(m3/h) |
40000 |
||
evaporator |
type |
Shell and tube |
|
chilled fluid flow(m3/h) |
21.03 |
||
volume(L) |
580 |
||
inlet and outlet pipe diameter (inch) |
2-1/2 |
||
pump |
power (kw) |
4 |
|
flow rate(m3/h) |
25 |
||
Bar |
4 |
||
safety protection |
compressor over temperature, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing |
||
weight |
kg |
1250 |
|
dimension |
mm |
2100*1660*2100 |
Some distinctive features of Air-cooled Chiller
1. Low installation cost. The central screw chiller system includes refrigeration loops, reservoirs, pumps, and components required for multiple processes to work throughout the plant, with fewer piping installations.
2. Convenient installation and maintenance. This air cooling center does not require the installation of cooling towers, as well as water treatment, water cooler condenser tube cleaning, cooling tower machinery maintenance.
3. Accurate temperature control ability. The freezing temperature can be accurate to ±1℃ to ensure the highest quality of the final product.
4. High efficiency. The central chiller system continuously measures environmental and process conditions and will adjust to operate in the most efficient manner.
Benefit of industrial chiller applications
1. The ability to maintain constant and precise control of the process temperature.
2. The cooling fluid can be delivered directly to the application heat source to increased production speed and ensure efficiency production
3. Accurate temperature control capability, to ensure the highest quality final products.
4. Water chiller systems prevent damage to heat-sensitive industrial components preventing undesirable repair downtime that might slow or even halt production altogether.
Air cooled industrial chiller installation and maintenance
Maintenance: Air cooled chiller does not need cooling tower, does not need water treatment, chiller condensate pipe cleaning, tower mechanical maintenance.
Installation: Most air-cooled chiller units are combined systems, including air-cooled fin condenser, evaporator compressor and evaporator. Some of these are built-in water storage tanks and pumps, which are designed and configured in the factory for optimum performance and reliability, which reduces design and simplifies installation.