Brand Name: | ANGES |
Model Number: | HBC-15 |
MOQ: | 1 |
Price: | Negotiation |
Packaging Details: | Plywood case |
Payment Terms: | T/T, L/C |
15hpAir Cooled Environmental-friendly Series Chiller 10Ton Injection Molding Chiller Blow Moulding Chiller for Plastic Industry Mold Cooling Chiller
Most plastic processes require cooling of some sort. Whether they are using injection molding, extruding plastic, blow molding, rotational molding, or thermoforming, all of these processes require cooling.
The cleanest and most recommended method of cooling is using a plastics chiller. A plastics chiller is a refrigerated device that cools plastics throughout the manufacturing process.
Injection Molding Chiller Specification
Model |
HBC-12 | ||
nominal cooling capacity | kcal/h | 30298 | |
kw | 35.2 | ||
input power | kw | 12.34 | |
power supply | 3PH/380V/50HZ | ||
refrigerant | type | R410a | |
type of control | Expansion valve | ||
compressor | type | hermetic scroll | |
power(kw) | 9.92 | ||
condenser | type | finned copper tube + low noise outer rotor fan | |
cooling air flow(m3/h) | 12000 | ||
evaporator | type | Shell and tube | |
chilled fluid flow(m3/h) | 6.07 | ||
volume(L) | 200 | ||
inlet and outlet pipe diameter (inch) | 2 | ||
pump | power (kw) | 1.5 | |
flow rate(m3/h) | |||
lift(m) | 20 | ||
safety protection | compressor over temperature, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing | ||
weight | kg | 530 | |
dimension | mm | 1530*780*1630 |
Nominal cooling capacity is according to:
Inlet chilled fluid temperature:17℃, Outlet chilled fluid temperature: 12℃.
Inlet cooling air temperature: 30℃, Outlet cooling air temperature:35℃.
The temperature range of chilled fluid is from 5℃ to 30℃.
The air cooled chillers are better to run while the ambient temperature is below 35°C.If not, the chillers will have high pressure alarm.Air-cooled chillers designed for high ambient temperatures are excluded.
Benefit of Plastic Process Chiller Applications
A chiller provides consistent temperature and pressure to your industrial process. Eliminating temperature and pressure variables simplifies the process development and optimization, ensuring the highest quality product. Instead of a wasteful, single-pass-through system, a chiller recirculates the cooling water.
Please tell these basic information so we can better quote you
1. your supply voltage (for example: 3HP380V220HZ)
2. the refrigerant you prefer
3. cooling capacity you need
How to ensure your product with good quality?
1. Since 2004, we specialize in the production of industrial chiller, located in Shenzhen, China, our quality priority. All products go through a rigorous multi-inspection process to give customers multiple guarantees, and most accessories are made from world-class brands such as Danfoss, Copeland, Schneider Electric Components, etc.
2. After the installation of the industrial chiller, we will fill nitrogen for 24 hours of pressure maintaining test to check whether there is leakage in the cooling system of the chiller.
3. During the chiller test, we will provide test videos and pictures.
4. After the completion of testing and commissioning of the chiller, the chiller unit shall be cleaned and labeled, and then inspected before leaving the factory. The chiller shall be packed with plywood to ensure that the chiller is in good condition during transportation.
Brand Name: | ANGES |
Model Number: | HBC-15 |
MOQ: | 1 |
Price: | Negotiation |
Packaging Details: | Plywood case |
Payment Terms: | T/T, L/C |
15hpAir Cooled Environmental-friendly Series Chiller 10Ton Injection Molding Chiller Blow Moulding Chiller for Plastic Industry Mold Cooling Chiller
Most plastic processes require cooling of some sort. Whether they are using injection molding, extruding plastic, blow molding, rotational molding, or thermoforming, all of these processes require cooling.
The cleanest and most recommended method of cooling is using a plastics chiller. A plastics chiller is a refrigerated device that cools plastics throughout the manufacturing process.
Injection Molding Chiller Specification
Model |
HBC-12 | ||
nominal cooling capacity | kcal/h | 30298 | |
kw | 35.2 | ||
input power | kw | 12.34 | |
power supply | 3PH/380V/50HZ | ||
refrigerant | type | R410a | |
type of control | Expansion valve | ||
compressor | type | hermetic scroll | |
power(kw) | 9.92 | ||
condenser | type | finned copper tube + low noise outer rotor fan | |
cooling air flow(m3/h) | 12000 | ||
evaporator | type | Shell and tube | |
chilled fluid flow(m3/h) | 6.07 | ||
volume(L) | 200 | ||
inlet and outlet pipe diameter (inch) | 2 | ||
pump | power (kw) | 1.5 | |
flow rate(m3/h) | |||
lift(m) | 20 | ||
safety protection | compressor over temperature, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing | ||
weight | kg | 530 | |
dimension | mm | 1530*780*1630 |
Nominal cooling capacity is according to:
Inlet chilled fluid temperature:17℃, Outlet chilled fluid temperature: 12℃.
Inlet cooling air temperature: 30℃, Outlet cooling air temperature:35℃.
The temperature range of chilled fluid is from 5℃ to 30℃.
The air cooled chillers are better to run while the ambient temperature is below 35°C.If not, the chillers will have high pressure alarm.Air-cooled chillers designed for high ambient temperatures are excluded.
Benefit of Plastic Process Chiller Applications
A chiller provides consistent temperature and pressure to your industrial process. Eliminating temperature and pressure variables simplifies the process development and optimization, ensuring the highest quality product. Instead of a wasteful, single-pass-through system, a chiller recirculates the cooling water.
Please tell these basic information so we can better quote you
1. your supply voltage (for example: 3HP380V220HZ)
2. the refrigerant you prefer
3. cooling capacity you need
How to ensure your product with good quality?
1. Since 2004, we specialize in the production of industrial chiller, located in Shenzhen, China, our quality priority. All products go through a rigorous multi-inspection process to give customers multiple guarantees, and most accessories are made from world-class brands such as Danfoss, Copeland, Schneider Electric Components, etc.
2. After the installation of the industrial chiller, we will fill nitrogen for 24 hours of pressure maintaining test to check whether there is leakage in the cooling system of the chiller.
3. During the chiller test, we will provide test videos and pictures.
4. After the completion of testing and commissioning of the chiller, the chiller unit shall be cleaned and labeled, and then inspected before leaving the factory. The chiller shall be packed with plywood to ensure that the chiller is in good condition during transportation.