5W Air Cooled Small Laser Chiller Unit Laser Cooling Machine

Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xProduct Name | Laser Chiller 5W | Compressor Type | Hermetic Scroll Compressor |
---|---|---|---|
Type | Air-cooled Type | Refrigerant | R22/R404a/R407c/R134a |
Evaporator | Plate Heat Exchanger Or Tank With Coil Or Shell And Tube | Condenser | High Efficiency Air-cooled Fin Heat Exchanger |
High Light | Small Laser Chiller Unit,Air Cooled Laser Chiller Unit,5W small air cooled chiller |
Laser Chiller 5W Air Cooled Small Chiller Laser Cooling Machine Laser Cutting Cooling Cooling Laser
Laser chiller
Laser chiller is a kind of water cooling equipment, can provide constant temperature, constant current, constant pressure cooling water. Laser water cooler is mainly used in laser marking machine, laser engraving machine, laser welding machine, laser injet machine, laser cutting machine and other laser processing equipment, it can precisely control the temperature required by laser equipment, so as to ensure the normal work of laser equipment.
Industrial Laser Chiller Specification
Item |
AL-5W |
|
Nominal cooling capacity | Kcal/h | 12470 |
kw | 14.5 | |
Input power | kw | 5.33 |
Power supply | 3PH~380V/50HZ | |
Refrigerant | Type | R22 |
Type of control | Capillary | |
Compressor | Type | Hermetic scroll type |
Power (kw) | 4.4 | |
Condenser | Type |
Finned copper tube+low noise outer rotor fan |
Power(kw) | 0.38 | |
Cooling air flow | 5000 | |
Evaporator | Type | Water tank with coil |
Chilled water flow | 2.50 | |
Tank volume(L) | 60 | |
Inlet/outlet pipe chiller(inch) | 1 | |
Water pump | Power(KW) | 0.55 |
Lift(m) | 22 | |
Safety protection | compressor over temperature, over-current protection, high and low pressure protection, over -temperature protection ,flow switch protection,phase sequence or missing phase protection,exhaust overheating protection | |
Net weight | kg | 175 |
Dimension | mm | 1140*560*1250 |
Why do I need a industrial water chiller?
Industrial chillers are used for controlled cooling of products, mechanisms and machinery in a variety of industries. A chiller removes heat from the process water and transfers it to air via a heat exchanger.Industrial water chiller can keep your equipment at a safe operating temperature and cool your components during processes to ensure the highest quality final products and reduce production cycle time.
Main components
Laser chiller is mainly composed of water tank, compressor, condenser, evaporator, capillary and so on.
Industrial chiller application
Laser chiller provides constant temperature, constant current, constant pressure environment in medical, electroplating, plastic, numerical control and other industries.
Featurers for laser cutting chiller
1.Laser chiller use the world famous hermetic scroll type compressor, features low noise, low vibration, low energy consumption and high efficiency.
2.Laser chiller use environmental refrigerant R410a or R134a.
3.Air cooled laser chiller use finned copper tube and low noise outer rotor fan, without cooling water system, save water.
4.High efficient shell and tube type or plack pack evaporator, built-in stainless steel 304 water tank, easy to install and use.
5.Chiller has accurate temperature control capability, the chilled water temperature can be accurate to ± 0.5 ℃.
6.The air coole package laser chiller has contains water tank and the pump and all necessary components, portable and easier installation.
1.The laser chiller cooling provide constant and precise cold water to the laser process temperature.
2.The water chiller precise temperature control can improve the machining accuracy of laser machine and productivity for laser process.
3.Air cooled laser chiller design is very compact and made of high-grade materials. It has stronger durability and longer service life.
4.Chillers can decrease equipment depreciation and degradation to cut down on operating expenditures.
1.Install the chiller in a ventilated and clean place, ambient temperature below 40 ℃ is recommended and maintain good ventilation.
2.The water should be replaced regularly, and the water tank should be cleaned regularly. Generally, the water should be changed once every 3 months.
3.The quality and temperature of the circulating water will affect the service life of the laser tube, so it is recommended to use pure water.
4.When the lase chiller stops due to fault alarm, must check the cause of the fault. Do not forcibly start the chiller before troubleshooting.
5.Regularly clean the condenser and dust filter of the chiller.
6.If there is no emergency during use, do not arbitrarily shut down the chiller by cutting off the power supply.
7.Winter maintenance in addition to routine maintenance, there is also the need to prevent icing. In order to ensure the normal use of laser chiller, the ambient temperature should not be lower than 5 ℃.If not, add antifreeze solution appropriately.