Send Message
Good price  online

products details

Home > Products >
Screw Type Chiller
>
100hp Water-cooled Screw Type Chiller With Hanbell Compressor Use For Cooling Mixing Tank

100hp Water-cooled Screw Type Chiller With Hanbell Compressor Use For Cooling Mixing Tank

Brand Name: ANGES
Model Number: 100HP
MOQ: 1
Packaging Details: Plywood case
Payment Terms: T/T, L/C
Detail Information
Place of Origin:
China
Compressor:
Hanbell
Expansion Valve:
Emerson
Condenser:
ANGES
Evaporator:
ANGES
Solenoid Valve:
Emerson
Drying Filter:
Emerson
Oil Pressure Gauge:
REFCO
Touch Screen:
WEINTEK
PLC Controller:
Siemens
Electrical Components:
Schneider
Fan:
Nangbeng
Highlight:

100hp Water-cooled Screw Chiller

,

Hanbell Compressor Screw Chiller

,

Mixing Tank Screw Chiller

Product Description

100hp Water-cooled  Screw Type Chiller with Hanbell Compressor Use For Cooling Mixing Tank
The chiller for cooling the mixing tank is a refrigerating machine that transfers the coldness of the chilled water to the material in the reactor through the jacket or coil of the reactor, and cools the material in the form of indirect cooling. The circulation of the chilled water is mainly achieved by a low-temperature circulation pump, and the chilled water is produced by a chiller. It is not affected by the external environment and the chilled water temperature can be set by yourself.
 

Water-cooled Low Temperature Screw Type Chiller Specification

 

Model

Item

AGS-100WSH
nominal cooling capacity kcal/h 321554
kw 373.9
input power kw 73.9
max running current A 168.4
power supply 3PH-380V-50HZ
refrigerant type R22
type of control expansion valve
compressor type semi-hermetic screw
quantity 1
start-up mode Y-△
capacity control 0-25-50-75-100
evaporator type shell and tube
chilled fluid flow (m3/h) 64.3
pipe diameter (inch) 4
condenser type shell and tube
cooling water flow (m3/h) 77
pipe diameter (inch) 4
safety protection compressor over temperature protection, over load protection, high and low pressure protection, flow switch protection, reversed and lacking phase protection, anti-freezing protection,fusible protection.
dimension mm 3500*1050*1600
net weight kg 1720
running weight kg 1960
 

Principle of refrigeration system

 

  1. The principle of the refrigeration system of the chiller for cooling the mixing tank, the ice machine for cooling the mixing tank, and the freezing water machine for cooling the mixing tank is that the low-temperature and low-pressure liquid refrigerant exchanges heat with the surrounding water in the evaporator. The evaporator absorbs the heat of the water and evaporates into a low-temperature and low-pressure gas.
  2.  
  3. The temperature of the refrigerant remains unchanged during the evaporation process. The low-temperature and low-pressure gaseous refrigerant enters the compressor, is compressed by the compressor, and is compressed into a high-temperature and high-pressure gas, and then enters the condenser, where it exchanges heat with the indoor medium.
  4.  
  5. Part of the heat of the high-temperature and high-pressure gas is absorbed by the medium, the temperature of the medium rises, and the refrigerant releases heat to the condenser to become a high-temperature and high-pressure liquid.
  6.  
  7. The temperature of the condenser process remains unchanged, and then enters the expansion valve for throttling. Throttling is a process of rapid cooling, and the refrigerant becomes a low-temperature and low-pressure liquid.
  8.  
  9. After this process, the refrigerant enters the evaporator for heat exchange and evaporation, thereby realizing the entire process of the refrigeration system. This cycle is continuous, and water can be continuously cooled.

 
How to select the model of the chiller ?

  1. In the production process, the injection molding machine needs to cool the mold to achieve rapid condensation of plastic, improve product quality, and improve production efficiency.

  2. Here, the chiller is indispensable. Chiller used in injection molding machine, through extrusion, blow bottle, thermoplastic, hydraulic system four steps to achieve rapid condensation of plastic.

  3. This shows the importance of the chiller to the injection molding machine. In the selection of chiller should pay attention to:

  4. In mold cooling, the choice of ice water energy depends on its specific heat capacity with the molding material, the temperature at the time of sol, the weight, and the temperature at the time of product release.

  5. In terms of temperature difference, the smaller the temperature difference, the more ice water flow is required to carry away the same heat, and the smaller the ice water flow is require

 

 
 100hp Water-cooled Screw Type Chiller With Hanbell Compressor Use For Cooling Mixing Tank 0100hp Water-cooled Screw Type Chiller With Hanbell Compressor Use For Cooling Mixing Tank 1
 

Products Details

Home > Products >
Screw Type Chiller
>
100hp Water-cooled Screw Type Chiller With Hanbell Compressor Use For Cooling Mixing Tank

100hp Water-cooled Screw Type Chiller With Hanbell Compressor Use For Cooling Mixing Tank

Brand Name: ANGES
Model Number: 100HP
MOQ: 1
Packaging Details: Plywood case
Payment Terms: T/T, L/C
Detail Information
Place of Origin:
China
Brand Name:
ANGES
Model Number:
100HP
Compressor:
Hanbell
Expansion Valve:
Emerson
Condenser:
ANGES
Evaporator:
ANGES
Solenoid Valve:
Emerson
Drying Filter:
Emerson
Oil Pressure Gauge:
REFCO
Touch Screen:
WEINTEK
PLC Controller:
Siemens
Electrical Components:
Schneider
Fan:
Nangbeng
Minimum Order Quantity:
1
Packaging Details:
Plywood case
Delivery Time:
30 days
Payment Terms:
T/T, L/C
Highlight:

100hp Water-cooled Screw Chiller

,

Hanbell Compressor Screw Chiller

,

Mixing Tank Screw Chiller

Product Description

100hp Water-cooled  Screw Type Chiller with Hanbell Compressor Use For Cooling Mixing Tank
The chiller for cooling the mixing tank is a refrigerating machine that transfers the coldness of the chilled water to the material in the reactor through the jacket or coil of the reactor, and cools the material in the form of indirect cooling. The circulation of the chilled water is mainly achieved by a low-temperature circulation pump, and the chilled water is produced by a chiller. It is not affected by the external environment and the chilled water temperature can be set by yourself.
 

Water-cooled Low Temperature Screw Type Chiller Specification

 

Model

Item

AGS-100WSH
nominal cooling capacity kcal/h 321554
kw 373.9
input power kw 73.9
max running current A 168.4
power supply 3PH-380V-50HZ
refrigerant type R22
type of control expansion valve
compressor type semi-hermetic screw
quantity 1
start-up mode Y-△
capacity control 0-25-50-75-100
evaporator type shell and tube
chilled fluid flow (m3/h) 64.3
pipe diameter (inch) 4
condenser type shell and tube
cooling water flow (m3/h) 77
pipe diameter (inch) 4
safety protection compressor over temperature protection, over load protection, high and low pressure protection, flow switch protection, reversed and lacking phase protection, anti-freezing protection,fusible protection.
dimension mm 3500*1050*1600
net weight kg 1720
running weight kg 1960
 

Principle of refrigeration system

 

  1. The principle of the refrigeration system of the chiller for cooling the mixing tank, the ice machine for cooling the mixing tank, and the freezing water machine for cooling the mixing tank is that the low-temperature and low-pressure liquid refrigerant exchanges heat with the surrounding water in the evaporator. The evaporator absorbs the heat of the water and evaporates into a low-temperature and low-pressure gas.
  2.  
  3. The temperature of the refrigerant remains unchanged during the evaporation process. The low-temperature and low-pressure gaseous refrigerant enters the compressor, is compressed by the compressor, and is compressed into a high-temperature and high-pressure gas, and then enters the condenser, where it exchanges heat with the indoor medium.
  4.  
  5. Part of the heat of the high-temperature and high-pressure gas is absorbed by the medium, the temperature of the medium rises, and the refrigerant releases heat to the condenser to become a high-temperature and high-pressure liquid.
  6.  
  7. The temperature of the condenser process remains unchanged, and then enters the expansion valve for throttling. Throttling is a process of rapid cooling, and the refrigerant becomes a low-temperature and low-pressure liquid.
  8.  
  9. After this process, the refrigerant enters the evaporator for heat exchange and evaporation, thereby realizing the entire process of the refrigeration system. This cycle is continuous, and water can be continuously cooled.

 
How to select the model of the chiller ?

  1. In the production process, the injection molding machine needs to cool the mold to achieve rapid condensation of plastic, improve product quality, and improve production efficiency.

  2. Here, the chiller is indispensable. Chiller used in injection molding machine, through extrusion, blow bottle, thermoplastic, hydraulic system four steps to achieve rapid condensation of plastic.

  3. This shows the importance of the chiller to the injection molding machine. In the selection of chiller should pay attention to:

  4. In mold cooling, the choice of ice water energy depends on its specific heat capacity with the molding material, the temperature at the time of sol, the weight, and the temperature at the time of product release.

  5. In terms of temperature difference, the smaller the temperature difference, the more ice water flow is required to carry away the same heat, and the smaller the ice water flow is require

 

 
 100hp Water-cooled Screw Type Chiller With Hanbell Compressor Use For Cooling Mixing Tank 0100hp Water-cooled Screw Type Chiller With Hanbell Compressor Use For Cooling Mixing Tank 1