20ton industrial air cooled chiller units for Industrial process cooling machince 40hp Air cooled chiller unit
Product Description for 40HP 20ton 120.4kw Industrial Air Cooled Chiller for Brewery Fermenting Tanks for Beverage Milk Cooling System with CE
Product Name: Industrial air cooled screw type chiller
Cooling capacity: 120.4kw/40hp
Output temp. :5-35C
Power supply: 3PH/220V, 380-415V, 440V-460V/50Hz or 60Hz;
Color: grey or customized
Refrigerant: R22/R407C/R134a/R410a
Compressor:Hermetic scroll type,world famous brand compressors from Copland, Panasonic etc
Injection Molding Chiller Specification
Model Item |
ACK-40(F) | |
Nominal cooling capacity | Kcal/h | 103544 |
kw | 120.4 | |
Input power | kw | 39.2 |
Power supply | 3PH/380V/50HZ | |
Refrigerant | Type | R22 |
Type of control | Expansion valve | |
Compressor | Type | Hermetic scroll type |
Power (kw) | 32.4 | |
Condenser | Type |
Finned copper tube+low noise outer rotor fan |
Fan | Power(kw) | 2.8 |
Cooling air flow | 40000 | |
Evaporator | Type | Shell and tube |
Chilled water flow | 20.76 | |
Tank volume(L) | 240 | |
Inlet/outlet pipe chiller( inch) | 2-1/2" | |
Water pump | Power(KW) | 4 |
Lift(m) | 22 | |
Safety protection | compressor over temperature, over-current protection, high and low pressure protection, over -temperature protection ,flow switch protection,phase sequence or missing phase protection,exhaust overheating protection | |
Net weight | kg | 1250 |
Dimension | mm | 2100*1660*2100 |
Anges chiller Application Range.
THE AFTER-SALE SERVICE OF ANGES CHILLER!
FAQ
1.How does a chiller system work?
Chiller has two circulation,one is process water circulation,the other is refrigerant gas circulation.Heat picked up from the process.Heat transfers to refrigerant circulation.Heat is remove to air or water.
2.How to calculate cooling capacity for chillers?
Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-t2)/0.86
Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)
3.How can we do for chiller maintenance ?
Check the temperature of the chilled water entering and leaving the chiller system.
Check and verify the temperature of the condenser water entering and leaving the system.
Check compressor power consumption and current.
Check oil sump oil level and temperature.
Check condenser and evaporator pressures.
Check and record oil pressure readings.
Check chiller system for abnormal noise and vibration.