Brand Name: | ANGES |
Model Number: | 150HP |
MOQ: | 1 |
Packaging Details: | Plywood case |
Payment Terms: | T/T, L/C |
Water Chiller Chilled Water Cooled Chiller Water Cooled Chiller Manufacturers Water Cooled Chiller Molding Machine
The difference between Air-cooled chiller and Water-cooled chiller
An air-cooled chiller refers to a chiller system that uses the ambient air surrounding the condensing unit to cool and condense the refrigerant back into a liquid. In other words, the air cooled chillers use fans for chiller's refrigerant dissipate heat, but the water-cooled needs to install cooling tower for operation.Water-cooled chillers are more efficient with the disadvantage of having critical maintenance demands included water treatment, chiller condenser-tube cleaning, tower mechanical maintenance, and freeze protection.This system includes item below.
Water-cooled chiller
Cooling tower
Cooling pump
Insulated water storage tank
Internal circulating pump and External process circulating pump
Screw chiller i and heat extraction as it is vital to yield high quality products. This includes process such as plastic injection, plastic extruding, bottle blowing, film blowing and many other thermoplastic materials that need to be heated to their molten temperature and then be solidified through cooling water from industrial chiller.
Water-cooled screw chiller specification
Model |
AGS-150WDH | |
nominal cooling capacity | kcal/h | 463884 |
kw | 539.4 | |
input power | kw | 112.2 |
max running current | A | 255.7 |
power supply | 3PH-380V-50HZ | |
refrigerant | type | R22 |
type of control | expansion valve | |
compressor | type | semi-hermetic screw |
Power(kw) | 56.1×2 | |
start-up mode | Y-△ | |
capacity control | 0-25-50-75-100 | |
evaporator | type | shell and tube |
chilled fluid flow (m3/h) | 92.8 | |
pipe diameter (inch) | 5 | |
condenser | type | shell and tube |
cooling water flow (m3/h) | 112 | |
pipe diameter (inch) | 5 | |
safety protection | compressor over temperature protection, over load protection, high and low pressure protection, flow switch protection, reversed and lacking phase protection, anti-freezing protection,fusible protection. | |
dimension | mm | 3860*750*1750 |
net weight | kg | 2610 |
running weight | kg | 2860 |
Water-cooled screw chiller featurers
Advantage of water cooling chiller
Benefits of an industrial water chiller
Brand Name: | ANGES |
Model Number: | 150HP |
MOQ: | 1 |
Packaging Details: | Plywood case |
Payment Terms: | T/T, L/C |
Water Chiller Chilled Water Cooled Chiller Water Cooled Chiller Manufacturers Water Cooled Chiller Molding Machine
The difference between Air-cooled chiller and Water-cooled chiller
An air-cooled chiller refers to a chiller system that uses the ambient air surrounding the condensing unit to cool and condense the refrigerant back into a liquid. In other words, the air cooled chillers use fans for chiller's refrigerant dissipate heat, but the water-cooled needs to install cooling tower for operation.Water-cooled chillers are more efficient with the disadvantage of having critical maintenance demands included water treatment, chiller condenser-tube cleaning, tower mechanical maintenance, and freeze protection.This system includes item below.
Water-cooled chiller
Cooling tower
Cooling pump
Insulated water storage tank
Internal circulating pump and External process circulating pump
Screw chiller i and heat extraction as it is vital to yield high quality products. This includes process such as plastic injection, plastic extruding, bottle blowing, film blowing and many other thermoplastic materials that need to be heated to their molten temperature and then be solidified through cooling water from industrial chiller.
Water-cooled screw chiller specification
Model |
AGS-150WDH | |
nominal cooling capacity | kcal/h | 463884 |
kw | 539.4 | |
input power | kw | 112.2 |
max running current | A | 255.7 |
power supply | 3PH-380V-50HZ | |
refrigerant | type | R22 |
type of control | expansion valve | |
compressor | type | semi-hermetic screw |
Power(kw) | 56.1×2 | |
start-up mode | Y-△ | |
capacity control | 0-25-50-75-100 | |
evaporator | type | shell and tube |
chilled fluid flow (m3/h) | 92.8 | |
pipe diameter (inch) | 5 | |
condenser | type | shell and tube |
cooling water flow (m3/h) | 112 | |
pipe diameter (inch) | 5 | |
safety protection | compressor over temperature protection, over load protection, high and low pressure protection, flow switch protection, reversed and lacking phase protection, anti-freezing protection,fusible protection. | |
dimension | mm | 3860*750*1750 |
net weight | kg | 2610 |
running weight | kg | 2860 |
Water-cooled screw chiller featurers
Advantage of water cooling chiller
Benefits of an industrial water chiller