Send Message
Good price  online

products details

Home > Products >
Glycol Chiller
>
Brewery Portable Glycol Chiller 10 Ton Glycol Refrigerant Low Temperature Water Chiller Refrigerator Water Chiller

Brewery Portable Glycol Chiller 10 Ton Glycol Refrigerant Low Temperature Water Chiller Refrigerator Water Chiller

Brand Name: ANGES
Model Number: 10HP
MOQ: 1
Packaging Details: Plywood case
Payment Terms: T/T, L/C
Detail Information
Place of Origin:
China
Refrigerant:
R404a
Cooling Capacity:
10ton At Water Outlet -25 ℃
Compressor:
Piston Compressor
Condenser:
Finned Copper Tube
Evaporator:
Plate Heat Exchanger
Condition:
Brandnew
Name:
Brewery Glycol Chiller, Beer Chiller Unit
After-sales Service Provided:
Video Technical Support,Overseas Third-party Support Available,Online Support
High Light:

Brewery Portable Glycol Chiller

,

Portable Glycol Chiller 10 Ton

,

Low Temperature Brewery Glycol Chiller

Product Description

Brewery Glycol Chiller Glycol Refrigerant Low Temperature Water Chiller Refrigerator Water Chiller​

 

Low Temperature Glycol Chiller 

Low temperature glycol chiller is a kind of water cooling equipment, it can provide a constant temperature, constant current, constant pressure of a cooling equipment. The glycol chiller water is between -5℃ and -40℃ and the chilled water will be transported to the equipment or products that need cooling through chiller pump.

 

What is air cooled chiller?

Air-cooled chiller is built-in insulation water tank and water pump, no need to add another cooling tower to heat. It is very easy to install and move. But it has high requirements on the working environment. It is cooled by hot air circulation, so if the ventilation effect of the installation workshop is not good, it will directly affect the refrigeration effect of the chiller.

 

Application

Industrial glycol water chiller unit is used to cool the hot parts of the equipment, so that the equipment can work normally at low temperature. Used in Beverage filling, spindle cooling, CNC machine tools, grinding miller, reaction system, welding machine, cutting machine and other equipment, temperature adjustment range can be 40 degrees below zero.

 

Specification

 

Item

AC-10L
nominal cooling capacity kcal/h 4651
  kw 5.41
input power kw 9.4
power supply 3PH~380V 50HZ
refrigerant type R404a
  type of control expansion valve
compressor type hermetic scroll(piston)
  power(kw) 7.5
condenser type finned copper tube + low noise outer rotor fan
evaporator type Plate heat exchanger
  chilled fluid flow (m3/h) 2.61
  inlet and outlet pipe diameter (inch) 1-1/2
pump power (kw) 1.1
  lift(m) 20
safety protection compressor over temperature, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing
dimension mm 1530*780*1630
weight kg 450


The nominal cooling capacity is according to: Inlet chilled fluid temperature: -20℃,outlet chilled fluid temperature: -25℃Note: 

 

Features of glycol cooling system

  • The glycol small water chiller use semi-closed piston compressor, high refrigeration efficiency, excellent performance.
  • The air cooled glycol water chiller has perfect energy control system.The unit temperature controller can automatically adjust the stop and start of the unit according to the change of load.
  • Glycol solution can be used as a secondary refrigerant. The industrial glycol chiller outlet temperature of chilled water can reach -40 ℃.
  • Air-cooled glycol chiller do not need to be equipped with cooling pump and cooling tower, easy to install, suitable for production site shortage areas.
  • The chiller condenser and evaporator of small refrigerator adopt internal thread heat transfer tube, choose world famous brand fully enclosed compressor, has the advantages of compact structure, small volume, light weight and so on.

The proportion of Ethylene Glycol Aqueous Solution of glycol water chiller unit

Operating temperature Concentration Density Specific heat capacity Heat conductivity Viscosity Freezing point
% ×10³ Kg/m³ KJ/(kg.k) W/m.k Pa.s
0 25 1.03 3.834 0.511 3.8 -10.6
-10 35 1.063 3.561 0.4726 7.3 -17.8
-20 45 1.08 3.312 0.441 21 -26.6
-30 55 1.097 2.975 0.3725 90 -41.6

 


 

 

 

 

 

Products Details

Home > Products >
Glycol Chiller
>
Brewery Portable Glycol Chiller 10 Ton Glycol Refrigerant Low Temperature Water Chiller Refrigerator Water Chiller

Brewery Portable Glycol Chiller 10 Ton Glycol Refrigerant Low Temperature Water Chiller Refrigerator Water Chiller

Brand Name: ANGES
Model Number: 10HP
MOQ: 1
Packaging Details: Plywood case
Payment Terms: T/T, L/C
Detail Information
Place of Origin:
China
Brand Name:
ANGES
Model Number:
10HP
Refrigerant:
R404a
Cooling Capacity:
10ton At Water Outlet -25 ℃
Compressor:
Piston Compressor
Condenser:
Finned Copper Tube
Evaporator:
Plate Heat Exchanger
Condition:
Brandnew
Name:
Brewery Glycol Chiller, Beer Chiller Unit
After-sales Service Provided:
Video Technical Support,Overseas Third-party Support Available,Online Support
Minimum Order Quantity:
1
Packaging Details:
Plywood case
Delivery Time:
25 days
Payment Terms:
T/T, L/C
High Light:

Brewery Portable Glycol Chiller

,

Portable Glycol Chiller 10 Ton

,

Low Temperature Brewery Glycol Chiller

Product Description

Brewery Glycol Chiller Glycol Refrigerant Low Temperature Water Chiller Refrigerator Water Chiller​

 

Low Temperature Glycol Chiller 

Low temperature glycol chiller is a kind of water cooling equipment, it can provide a constant temperature, constant current, constant pressure of a cooling equipment. The glycol chiller water is between -5℃ and -40℃ and the chilled water will be transported to the equipment or products that need cooling through chiller pump.

 

What is air cooled chiller?

Air-cooled chiller is built-in insulation water tank and water pump, no need to add another cooling tower to heat. It is very easy to install and move. But it has high requirements on the working environment. It is cooled by hot air circulation, so if the ventilation effect of the installation workshop is not good, it will directly affect the refrigeration effect of the chiller.

 

Application

Industrial glycol water chiller unit is used to cool the hot parts of the equipment, so that the equipment can work normally at low temperature. Used in Beverage filling, spindle cooling, CNC machine tools, grinding miller, reaction system, welding machine, cutting machine and other equipment, temperature adjustment range can be 40 degrees below zero.

 

Specification

 

Item

AC-10L
nominal cooling capacity kcal/h 4651
  kw 5.41
input power kw 9.4
power supply 3PH~380V 50HZ
refrigerant type R404a
  type of control expansion valve
compressor type hermetic scroll(piston)
  power(kw) 7.5
condenser type finned copper tube + low noise outer rotor fan
evaporator type Plate heat exchanger
  chilled fluid flow (m3/h) 2.61
  inlet and outlet pipe diameter (inch) 1-1/2
pump power (kw) 1.1
  lift(m) 20
safety protection compressor over temperature, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing
dimension mm 1530*780*1630
weight kg 450


The nominal cooling capacity is according to: Inlet chilled fluid temperature: -20℃,outlet chilled fluid temperature: -25℃Note: 

 

Features of glycol cooling system

  • The glycol small water chiller use semi-closed piston compressor, high refrigeration efficiency, excellent performance.
  • The air cooled glycol water chiller has perfect energy control system.The unit temperature controller can automatically adjust the stop and start of the unit according to the change of load.
  • Glycol solution can be used as a secondary refrigerant. The industrial glycol chiller outlet temperature of chilled water can reach -40 ℃.
  • Air-cooled glycol chiller do not need to be equipped with cooling pump and cooling tower, easy to install, suitable for production site shortage areas.
  • The chiller condenser and evaporator of small refrigerator adopt internal thread heat transfer tube, choose world famous brand fully enclosed compressor, has the advantages of compact structure, small volume, light weight and so on.

The proportion of Ethylene Glycol Aqueous Solution of glycol water chiller unit

Operating temperature Concentration Density Specific heat capacity Heat conductivity Viscosity Freezing point
% ×10³ Kg/m³ KJ/(kg.k) W/m.k Pa.s
0 25 1.03 3.834 0.511 3.8 -10.6
-10 35 1.063 3.561 0.4726 7.3 -17.8
-20 45 1.08 3.312 0.441 21 -26.6
-30 55 1.097 2.975 0.3725 90 -41.6