xType | Water Cooled Inverter Chiller | Refrigerant | R134a/R407c/R410a |
---|---|---|---|
Cooling Capacity | 5HP | Compressor Type | Inverter Scroll Chiller |
Pump | 2bar- 6bar | Evaporator | Shell And Tube |
Condenser | Shell And Tube ,Plater Heat Exchanger | Application | Industrial Cooling Solutions |
High Light | 5HP Inverter Water Chiller,Inverter Water Chiller 5HP,5HP portable water chiller |
Water Chiller Inverter Chiller Water Cooled Small Chiller Water Chiller VFD Chiller Energy Efficient Chiller
About the inverter chiller
Water chiller with non-inverter type compressor remains constant water temperature by adjusting the compressor's ON and OFF, which consumes more energy.
In inverter type water chiller,water temperature is adjusted by changing compressor motor speed instead of ON and OFF.
Compared to non-inverter type water chiller, the inverter chiller has less power loss and can save in energy.
Variable-speed chillers offer an alternative for process cooling applications.The controller continuously monitors the heat load from the production process to slow down or speed up the compressor motor for peak efficiency and temperature control.
Inverter chiller specification
Item |
AWV-5 | |
Nominal cooling capacity | Low frequency kcal/h | 3333 |
High frequency kcal/h | 11997 | |
Low frequency kw | 3.88 | |
High frequency kw | 13.95 | |
Input power | Low frequency kw | 1.53 |
High frequency kw | 3.54 | |
Power | Variable frequency power supply | |
Refrigerant | Type | R410a |
Type of control | Electronic expansion valve | |
Compressor | Type | Hermetic motor driven compressor |
Low frequency power( kw) | 0.78 | |
High frequency power (kw) | 2.79 | |
Condenser | Type | Shell and tube |
Cooling water flow (m3/h) | 2.9 | |
Inlet and outlet pipe caliber(inch) | 1-1/2 | |
Evaporator | Type | Water tank with coil |
Chilled water flow (m3/h) | 2.4 | |
T | Tank volume(L) | 60 |
Inlet and outlet pipe caliber(inch) | 1 | |
Pump | Power (kw) | 0.75 |
Lift(m) | 20 | |
Safety protection | compressor over temperature, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing | |
Dimension | mm | 1040*500*940 |
Weight | kg | 150 |
Features and benefits of water cooled inverter chiller
- Energy saving. Inverter technology can ensure the best chiller performance. Chillers are able to run according to the heat load by adjust th speed of the compressor’s motor continuously which can result in consistent saving in operating costs.
- Capacity modulation adapts motor speed to vary load continuously, quickly, and smoothly for great comfort and reliability.
- Accurate temperature control. Advanced DC frequency conversion control technology is adopted to achieve high control accuracy, and the temperature control accuracy can reach ±0.1℃-±0.2℃.
- Low starting current.Frequency conversion soft start reduce the the impact of the power grid start, reduce the power distribution costs, safe and reliable in operation.
- Low acoustic level with variable-speed technology
- The COP efficiency of water-cooled chiller is relatively high, which is used in industrial process cooling and large-scale construction projects.
Chiller service
We are industrial chiller manufacturer, chiller service can be online support, video technical support, site service in some areas are available.
Site service will be done by our water chiller distributor, Indonesia, Philippines, Thailand, Singapore, Malaysia, Australia, United States, Israel, Egypt and so on.
How to ensure your product with good quality?
- We are specialized in producing industrial chiller since 2004, located in Shenzhen China and give top priority to our quality. All products pass strict multi inspection process which gives customers multi guarantee, most of the accessories use world-class brands, such as Danfoss, Copeland, Schneider electrical components and so on.
- After industrial chiller assembly, we will charge nitrogen for pressure maintaining testing for 24hrs, to check whether there is leakage in the chiller cooling system.
- We will provide testing videos, pictures during chiller testing.
- After the chiller testing commissioning, cleaning and labelling the chiller unit, then go for pre-delivery inspection before packing with plywood cases to to ensure that the chiller can be in good condition during transit.