Brand Name: ANGES
Model Number: Glycol chiller
MOQ: 1
Packaging Details: Plywood case
Payment Terms: T/T, L/C
Detail Information
Place of Origin:
China
Refrigerant:
R404a
Cooling Capacity:
16.71 Kw At Water Outlet -25 ℃
Compressor:
Piston Compressor
Condenser:
Finned Copper Tube
Evaporator:
Plate Heat Exchanger
Name:
Glycol Chiller
Type:
Air-cooled Water Chiller
Cold-coolant:
Glycol Solution, 50%
Chiller Show Room:
Chiller In Indonesia, Chiller In Philippines, Chiller In Malaysia, Chiller In USA,chiller In Mexico And So On
High Light:

Low Temperature air cooled glycol chiller

,

air cooled glycol chiller Low Temperature

,

Low Temperature Air Cooled Chiller Plant

Product Description

Air Cooled Glycol Chiller System Glycol Air Cooled Chiller Low Temperature Air Cooled Chiller Plant Brine Chiller

 

Glycol Chiller Low Temperature process chiller

Glycol chillers are industrial refrigeration systems that use for glycol mixed with water for anti-freezing, to lower the freezing point of the circulation water in the cooling system.

 

Air-cooled chiller is built-in insulation water tank and water pump, no need to add another cooling tower to heat. It is very easy to install and move. But it has high requirements on the working environment. It is cooled by hot air circulation, so if the ventilation effect of the installation workshop is not good, it will directly affect the refrigeration effect of the chiller.

 

Application

Industrial glycol water chiller unit is used to cool the hot parts of the equipment, so that the equipment can work normally at low temperature. Used in Beverage filling, spindle cooling, CNC machine tools, grinding miller, reaction system, welding machine, cutting machine and other equipment, temperature adjustment range can be 40 degrees below zero.

 

Specification

 

Model

 

AW-25L

 

nominal cooling capacity kcal/h 14367
at -25 ℃ kw 16.71
input power kw 20.95
power supply 3PH~380V 50HZ
refrigerant type R404a
  type of control expansion valve
compressor type hermetic scroll(piston)
  power(kw) 18.75
condenser type Shell and tube
  chilled fluid flow (m3/h) 15.80
  inlet and outlet pipe diameter (inch) 2
evaporator type Plate heat exchanger
  chilled fluid flow (m3/h) 8.07
  inlet and outlet pipe diameter (inch) 2
pump power (kw) 2.20
  lift(m) 20
safety protection compressor over temperature, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing
dimension mm 1950*950*1700
weight kg 1100

The nominal cooling capacity is according to: Inlet chilled fluid temperature: -20℃,outlet chilled fluid temperature: -25℃

 

Features of glycol cooling system

  • The glycol small water chiller use semi-closed piston compressor, high refrigeration efficiency, excellent performance.
  • Glycol solution can be used as a secondary refrigerant.The industrial glycol chiller outlet temperature of chilled water can reach -40 ℃.
  • The air cooled glycol chiller design is very compact and made by high-quality copper tube fin condensers, high efficiency plate heat exchanger, stable performance, low noise and long service life.
  • The glycol chiller with low temperature water has high pressure, low pressure, overload, water level, phase sequence and other protections to ensure the safe operation of the chiller unit.
  • The chiller water tank contains a floating ball automatic water replenishment device which is used to measure and control the water level, so as to effectively save time for customers and improve work efficiency.

 

The proportion of Ethylene Glycol Aqueous Solution of glycol water chiller unit

Operating temperature Concentration Density Specific heat capacity Heat conductivity Viscosity Freezing point
% ×10³ Kg/m³ KJ/(kg.k) W/m.k Pa.s
0 25 1.03 3.834 0.511 3.8 -10.6
-10 35 1.063 3.561 0.4726 7.3 -17.8
-20 45 1.08 3.312 0.441 21 -26.6
-30 55 1.097 2.975 0.3725 90 -41.6

 

How to ensure your product with good quality?

  1. We are specialized in producing industrial chiller since 2004, located in Shenzhen China and give top priority to our quality. All products pass strict multi inspection process which gives customers multi guarantee, most of the accessories use world-class brands, such as Danfoss, Copeland, Schneider electrical components and so on.
  2. After industrial chiller assembly, we will charge nitrogen for pressure maintaining testing for 24hrs, to check whether there is leakage in the chiller cooling system.
  3. We will provide testing videos, pictures during chiller testing.
  4. After the chiller testing commissioning, cleaning and labelling the chiller unit, then go for pre-delivery inspection before packing with plywood cases to to ensure that the chiller can be in good condition during transit.

How to select the model of the chiller ?

  1. We need to know the heat load of your process or chiller cooling capacity.
  2. Required water temperature, water pressure and flow rate.
  3. Application and power supply in local.
  4. Max. Ambient temperature in summer day
  5. Customized special specifications are acceptable. Contact us for more chiller Specification by number +86 13923791048.

 

 

 

 

Products Details

Home > Products >
Low Temperature Chiller
>
Low Temperature Air Cooled Glycol Chiller Air Cooled Chiller Plant

Low Temperature Air Cooled Glycol Chiller Air Cooled Chiller Plant

Brand Name: ANGES
Model Number: Glycol chiller
MOQ: 1
Packaging Details: Plywood case
Payment Terms: T/T, L/C
Detail Information
Place of Origin:
China
Brand Name:
ANGES
Model Number:
Glycol chiller
Refrigerant:
R404a
Cooling Capacity:
16.71 Kw At Water Outlet -25 ℃
Compressor:
Piston Compressor
Condenser:
Finned Copper Tube
Evaporator:
Plate Heat Exchanger
Name:
Glycol Chiller
Type:
Air-cooled Water Chiller
Cold-coolant:
Glycol Solution, 50%
Chiller Show Room:
Chiller In Indonesia, Chiller In Philippines, Chiller In Malaysia, Chiller In USA,chiller In Mexico And So On
Minimum Order Quantity:
1
Packaging Details:
Plywood case
Delivery Time:
25 days
Payment Terms:
T/T, L/C
High Light:

Low Temperature air cooled glycol chiller

,

air cooled glycol chiller Low Temperature

,

Low Temperature Air Cooled Chiller Plant

Product Description

Air Cooled Glycol Chiller System Glycol Air Cooled Chiller Low Temperature Air Cooled Chiller Plant Brine Chiller

 

Glycol Chiller Low Temperature process chiller

Glycol chillers are industrial refrigeration systems that use for glycol mixed with water for anti-freezing, to lower the freezing point of the circulation water in the cooling system.

 

Air-cooled chiller is built-in insulation water tank and water pump, no need to add another cooling tower to heat. It is very easy to install and move. But it has high requirements on the working environment. It is cooled by hot air circulation, so if the ventilation effect of the installation workshop is not good, it will directly affect the refrigeration effect of the chiller.

 

Application

Industrial glycol water chiller unit is used to cool the hot parts of the equipment, so that the equipment can work normally at low temperature. Used in Beverage filling, spindle cooling, CNC machine tools, grinding miller, reaction system, welding machine, cutting machine and other equipment, temperature adjustment range can be 40 degrees below zero.

 

Specification

 

Model

 

AW-25L

 

nominal cooling capacity kcal/h 14367
at -25 ℃ kw 16.71
input power kw 20.95
power supply 3PH~380V 50HZ
refrigerant type R404a
  type of control expansion valve
compressor type hermetic scroll(piston)
  power(kw) 18.75
condenser type Shell and tube
  chilled fluid flow (m3/h) 15.80
  inlet and outlet pipe diameter (inch) 2
evaporator type Plate heat exchanger
  chilled fluid flow (m3/h) 8.07
  inlet and outlet pipe diameter (inch) 2
pump power (kw) 2.20
  lift(m) 20
safety protection compressor over temperature, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating, anti-freezing
dimension mm 1950*950*1700
weight kg 1100

The nominal cooling capacity is according to: Inlet chilled fluid temperature: -20℃,outlet chilled fluid temperature: -25℃

 

Features of glycol cooling system

  • The glycol small water chiller use semi-closed piston compressor, high refrigeration efficiency, excellent performance.
  • Glycol solution can be used as a secondary refrigerant.The industrial glycol chiller outlet temperature of chilled water can reach -40 ℃.
  • The air cooled glycol chiller design is very compact and made by high-quality copper tube fin condensers, high efficiency plate heat exchanger, stable performance, low noise and long service life.
  • The glycol chiller with low temperature water has high pressure, low pressure, overload, water level, phase sequence and other protections to ensure the safe operation of the chiller unit.
  • The chiller water tank contains a floating ball automatic water replenishment device which is used to measure and control the water level, so as to effectively save time for customers and improve work efficiency.

 

The proportion of Ethylene Glycol Aqueous Solution of glycol water chiller unit

Operating temperature Concentration Density Specific heat capacity Heat conductivity Viscosity Freezing point
% ×10³ Kg/m³ KJ/(kg.k) W/m.k Pa.s
0 25 1.03 3.834 0.511 3.8 -10.6
-10 35 1.063 3.561 0.4726 7.3 -17.8
-20 45 1.08 3.312 0.441 21 -26.6
-30 55 1.097 2.975 0.3725 90 -41.6

 

How to ensure your product with good quality?

  1. We are specialized in producing industrial chiller since 2004, located in Shenzhen China and give top priority to our quality. All products pass strict multi inspection process which gives customers multi guarantee, most of the accessories use world-class brands, such as Danfoss, Copeland, Schneider electrical components and so on.
  2. After industrial chiller assembly, we will charge nitrogen for pressure maintaining testing for 24hrs, to check whether there is leakage in the chiller cooling system.
  3. We will provide testing videos, pictures during chiller testing.
  4. After the chiller testing commissioning, cleaning and labelling the chiller unit, then go for pre-delivery inspection before packing with plywood cases to to ensure that the chiller can be in good condition during transit.

How to select the model of the chiller ?

  1. We need to know the heat load of your process or chiller cooling capacity.
  2. Required water temperature, water pressure and flow rate.
  3. Application and power supply in local.
  4. Max. Ambient temperature in summer day
  5. Customized special specifications are acceptable. Contact us for more chiller Specification by number +86 13923791048.