- Product Name:


Address: No.23 Limin Road, Gangtou Village, Bantian, Longgang District, Shenzhen, P.R. of China
ZipCode: 518129
Tel : 86-755-28227245/28227244/2827242
Fax: 86-755-28227243/89582800
Email: anges@agschiller.com
Friend Link :

air cooled screw chiller ( AGS-A series )


Company Profile Tel :86-755-28227245/28227244/2827242 Fax:86-755-28227243/89582800
Condensers details for ANGES screw chiller Model AGS-085ADH AGS-100ADH AGS-120ADH AGS-150ADH AGS-170ADH AGS-200ADH Item nominal cooling capacity kcal/h 180600 223600 275200 344000 399900 437740 kw 210 260 320 400 465 509 input power kw 72 86 99 134 146 168 max. running current A 182 232 244 330 430 500 power supply 3PH~380V 50HZ refrigerant type R22 /R407c refrigerating circuit 2 type of control thermostatic expansion valve compressor type semi-hermetic screw quantity 2 start-up mode Y- △ capacity control 0-25-50-75-100 condenser type air cooled type finned copper tube evaporator type shell and tube quantity 1 chilled fluid flow(m 3 /h) 36 45 55 69 80 88 safety protection compressor over temperature, unit overload, high and low pressure, flow switch, phase sequence, phase-missing, antifreezing net weight kg 2400 2700 3700 4000 4400 4800 running weight kg 2700 2950 4000 4350 4800 5200 Note: 1. nominal cooling capacity is according to: Inlet chilled fluid temperature: 12℃.Outlet chilled fluid temperature: 7℃. Inlet cooling air temperature: 35℃.Outlet cooling air temperature: 45℃. 2. working range: The temperature range of chilled fluid is from 5℃ to 20℃;
1.Shell and tube type condenser:
adopting the inner-thread or outer-thread copper tube,processed with advanced technique,and the professional tube expansion technology,the condenser is processed wholly by the CNC system,avoiding refrigerant leaking.
2.Finned tube type condenser:
Made of inported copper tube and hyperbolic corrugated hydrophilic aluminum foil and processed by specialized equipments,such high-speed punch process,that makes the copper tube and aluminum fins join more closely and the efficiency of heat exchanger much better. It features small volume,light weight, and compact structure.
Technical data of AGS-A series from AGS-085ADH~AGS-200ADH
Temperature difference between inlet and outlet chilled fluid is from 3℃ to 8℃.
The temperature difference between inlet and outlet cooling air is from 8℃ to 12℃;
Next Product >> none
Air cooled screw chiller - manufacturer search on: Google, Yahoo, Msn
Related Searches: air cooled screw chiller screw chiller chiller screw type air cooled chiller OEM chiller extruder line extruder machine Air cooled screw chiller room air conditioner air conditioning duct glycol chillers emergency cooling water cooled chillers air conditioning heating air conditioning coil chillers air cooled portable water cooling central ac systems room air conditioning unit air conditioning prices air conditioning unit cooling water machine